background image

Programmable Control Panel                 

                                           

 

PTN Electronics Limited                  9              www.PTN-electronics.com

 

5.3.2 Panel/Key setting 

There are three different colors of keys in the panel set of PS-WP. Add a key action to 
action list, then add events to this action, make this action will execute the events. 
Here take WP8-V for example, to introduce the uses of different buttons: 

 

1.  White keys: keys 1-8, correspond to the buttons on WP8. Click the key, it will pop 

up dialog as below: 

 

When select the type 

“Toggle”, the setting interface is as below: 

Key Action Type

 

1.  Press: Execute events 

when press button. 

2.  Release: Execute events 

when release button. 

3.  Page: Built-in most 4 

actions, actions need to 
be switched by other 
buttons, press to execute. 

4.  Toggle: Built-in most 4 

actions, actions will loop 
run when press. Actions 
can also be switched by 
other buttons, press to 
execute. 

Содержание WP8

Страница 1: ...Programmable Control Panel PTN Electronics Limited www PTN electronics com WP8 PTN Programmable Control Panel USER MANUAL Version WP82013V1 1 ...

Страница 2: ...ration instruction only not for any maintenance usage The functions described in this version are updated till May 2013 Any changes of functions and parameters since then will be informed separately Please refer to the dealers for the latest details This manual is copyright PTN Electronics Limited All rights reserved No part of this publication may be copied or reproduced without the prior written...

Страница 3: ...n 2 4 1 Introduction of the Interfaces 2 4 2 Connection of Programming and Looping 4 5 System Operations 5 5 1 Introductions of the Front Panel 5 5 2 USB Driver Installation 6 5 3 Software Programming 6 5 3 1 Main Menu 7 5 3 2 Panel Key setting 9 5 3 3 Action list 11 5 3 4 Event setting 11 5 3 5 Event List 20 6 System Diagram 21 7 Troubleshooting Maintenance 22 8 Safety Operation Guide 22 9 After ...

Страница 4: ... 1 x Power adapter DC 12V 4 x Captive screw connector 3 x IR emit probe 1 x Button labels 1 x User Manual Notes Please confirm if the product and the accessories are all included if not please contact with the dealers 2 Features Every button can be programmed to send the bi direction RS232 and RS485 commands simultaneously to control third party devices Every button can be programmed to send the i...

Страница 5: ...oftware PS WP Temperature 20 70 C Frequency Response 20Hz 20KHz Humidity 10 90 Power Supply 100VAC 240VAC 50 60 Hz Power Consumption 1W Case Dimensions Dual gang electron box 114x70 x28mm Product Weight 0 15kg 4 Connection Introduction 4 1 Introduction of the Interfaces Mini USB Connector 1 Communicate with PC which uses PS WP to program the buttons 2 Transmit the infrared data when learning IR Op...

Страница 6: ...ontrol other devices or looping output or connect with PC These two parts share the same grounding This port includes RS232 1 IR2 IR1 and RS485 a RS232 1 IR2 share the same port the detailed use depends on the setting of PS WP When be used as RS232 it is unidirectional transmission transmit data but without receive b IR1 for control other devices it can be programmable by the PS WP c RS485 the RS4...

Страница 7: ...y USB or RS232 working with the PS WP software It is shown as below Programming Connection Several pieces WP8 can be also looped to be a system for control more devices It is looped by the inter RS232 setting Please check the demo picture as below Several WP8 Looping connecting After connect the WP8 as above and then we should set the ID of each WP8 by PS WP The ID number is from 01 to 99 and it a...

Страница 8: ...ping connecting 5 System Operations 5 1 Introductions of the Front Panel Crystal and luminescent programmable buttons Every button can be programmable with PTN software PS WP Connect the PC via USB or RS232 And every label inside the button can be changeable You can choose the label you need and change it very easily like below For the specific transparent paper table please contact the local dist...

Страница 9: ...ver of USB we can use USB to program the WP8 5 3 Software Programming You can use this PTN software PS WP to easily set every button of WP8 After connect WP8 with PC by USB or RS232 we can open the PS WP to program the buttons for controlling The main window of PS WP has five parts main menu panel button setting event setting action list and event list In this manual we will take WP8 V for example...

Страница 10: ...he configuration to a file so that you can use the same configuration next time 2 System model includes WP8 H WP8 V WP19R etc and the buttons interface view are different with different models The pictures below show the differences between WP8 V and WP8 H NOTICE When select the model WP8 it will pop up Output Port Selection dialog user can select different RS and IR types depend on the uses of th...

Страница 11: ...32 1 IR2 RS232 2 IR3 RS232 3 RS485 RS232 1 2 RS232 2 IR2 RS232 1 IR3 IR2 3 3 Connection type the instructions are in the picture below The functions of WP8 s buttons will be available only after the programmed data is uploading successfully 4 Help Show the information of PS WP 1 Com connect by serial port 2 USB connect by mini USB 3 Disconnect disconnect the connection 4 Upload upload the programm...

Страница 12: ...the uses of different buttons 1 White keys keys 1 8 correspond to the buttons on WP8 Click the key it will pop up dialog as below When select the type Toggle the setting interface is as below Key Action Type 1 Press Execute events when press button 2 Release Execute events when release button 3 Page Built in most 4 actions actions need to be switched by other buttons press to execute 4 Toggle Buil...

Страница 13: ...l keys used in the loop function When use the loop function the ID must be set the ID can be 1 to 99 Press add will add the button to action list 3 Yellow Keys Keys 33 36 all are virtual keys Key 33 and 34 are for I O control which is not supported with WP8 Key 36 is a start action if add events to this action when the WP8 is power on it will execute the events in this action Key 35 is delay butto...

Страница 14: ...er 8 minutes 5 3 3 Action list Action list shows all the set actions An available action must be added to the list The action list is as the picture below 5 3 4 Event setting Event setting includes RS232 IR I O Relay Delay Compare LED Page Loop and Toggle setting Before set events an action must be added first The following introduction will show you the setting of each event RS232 Setting This it...

Страница 15: ...it Lib to create or edit a library file as below Notice When editing finish remember to save the editing and then press OK 2 There are two send types send once and send more times When select more times the send times and the delay between times can be set See in picture below Send Type Send Port Enter the serial command for device control Create delete the function name of the command Create open...

Страница 16: ...ent cannot be added 4 User can set the event name It is optional function not necessary IR Setting This item is used for setting the parameters of the WP8 s IR ports Click IR it will show as below 1 The data of IR need to be selected from library Click Change Lib to select a library file and open it Click Edit Lib to create or edit a library file as below ...

Страница 17: ...n be set See in picture below 3 The send port must be selected as the same as model setting otherwise the event cannot be added 4 The IR can set the carrier on off to turn on turn off the IR sending Select a function and then click learn press the IR remote button to send the IR code to infrared sensor port it will refresh the IR data Follow the same steps can learn any function of the remote butt...

Страница 18: ...ual Relay Setting This item is for the replay ports setting The setting is as the picture below Delay setting This item is to set a delay time user can add a delay between two events so when one event is finished it will delay a certain time then start another event The delay setting is as picture below Send Type Port Action On for connected Off for disconnected ...

Страница 19: ... selected as the same as model setting otherwise the event cannot be added And port 1 cannot be used for compare for there is no a receive pin in this port 2 User can set the event name it is optional function not necessary 3 For the events in one event list have priority from top to bottom so that the compare function can be used in action which with three or more events When send a serial comman...

Страница 20: ...e page action number Here take a example to show you the use of this function 1 Take button1 for example click key1 and select the action type page add the four actions to the action list Then add other four buttons press action to the list here take keys 5 8 for example 2 In event setting we add four different events to the four page actions of key1 and the four other keys will be added the page ...

Страница 21: ...ecute num1 more times b When press the button6 and then button1 the button1 will execute the event of num2 press button1 more times it will execute num2 more times c When press the button7 and then button1 the button1 will execute the event of num3 press button1 more times it will execute num3 more times d When press the button8 and then button1 the button1 will execute the event of num4 press but...

Страница 22: ...ly for the actions in it are loop running it will perform as below take the same example like page function a When press the button5 and then button1 the button1 will execute the event of num1 press button1 more times it will execute num2 then num3 num4 num1 and so on b When press the button6 and then button1 the button1 will execute the event of num2 press button1 more times it will execute num3 ...

Страница 23: ... When press the button8 and then button1 the button1 will execute the event of num4 press button1 more times it will execute num1 then num2 num3 num4 and so on 5 3 5 Event List The event list shows all events of the selected action and for each action of WP8 the most events can be added is ten The executing priority is from 1 to 10 see the picture below If there is an event execute incorrectly all...

Страница 24: ...ted 21 www PTN electronics com 6 System Diagram The WP8 can active different ports at one time It means every button can send the RS232 and RS485 commands IR code and control the relay at the same time The demo system diagram as below System Diagram ...

Страница 25: ...se loop function please reboot the WP8 8 Safety Operation Guide In order to guarantee the reliable operation of the equipments and safety of the staff please abide by the following proceeding in installation using and maintenance 1 The system must be earthed properly Please do not use two blades plugs and ensure the alternating power supply ranged from 100v to 240v and from 50Hz to 60Hz 2 Do not p...

Страница 26: ...e year warranty which starts from the first day you buy this product The purchase invoice shall prevail 4 Any problem is same with one of the following cases listed we will not offer warranty service but offer for charge Beyond the warranty Damage due to incorrectly usage keeping or repairing Damage due to device assembly operations by the maintenance company non assigned No certificate or invoice...