12
13
7. Terminal block P2, Pins 4, 5, and 6 are used for the relay. If a gate
operator or door strike is being triggered directly from this keypad,
the wires will connect to two of these three pins. Refer to the gate
or door strike manufacturer’s instructions to determine whether it
needs to be connected to the normally open and common or to the
common and normally closed.
8. The earth ground wire should be connected in situations where
the keypad is mounted on a wall that is wood, stone, or other
nonconductive material. It is not always necessary when it is
mounted on a bollard or gooseneck.
Note
: Uninsulated wires (Typically used for earth ground) cannot be located inside
the unit’s case. Make connections for uninsulated ground wire outside the case.
9. To connect the ground wire, run a copper wire from a grounded
water pipe or from a copper rod in the ground to the keypad and
connect it to the green earth ground wire using a wire nut. This
installation must meet applicable code as the type of wire, depth of
burial, and size of the rod may vary by municipality.
Terminal Block P1 (Left)
1. Red DC+ *
2. *
3. Black DC-
4.
5. Earth Ground if applicable
6.
* If using AC power, place the
AC wires in slots 1 and 2. We
recommend 12-18 VDC, but 12-18
VAC can be used.
Terminal Block P1 (Left)
1. White Data+
2. Shield **
3. Green Data-
4. Relay Normally Open Wire
5. Relay Common Wire
6. Relay Normally Closed Wire
** Shield wire should be insulated
with heat shrink or electrical tape.
Figure 13
Figure 14