WS1V Set Up Manual Rev. 7.8.30gll
NOTE 1
The users can set up the different weight units in various orders according to their
preference, and the amount of the chosen weight units can be up to 4.
(a) (b) (c) (d) (e)
(a)
⇒
The first weight unit (only “kg” or “g” are available to choose from). Select either 0 or 1.
(b)
⇒
The second weight unit (select one of the parameters listed below).
(c)
⇒
The third weight unit (select one of the parameters listed below).
(e)
⇒
The amount of the weight units selected (select one of parameters 1 ~ 4).
Available units:
0
⇒
kg
2
⇒
lb
5
⇒
oz
1
⇒
g
4
⇒
lb / oz
Hint:
When the first unit is set to lb, the second unit will be kg or g.
For example:
Select two weight units, kg and lb, with kg as the calibration weight unit.
The Calibration
weight unit is entered first. In this example enter 02002
NOTE 2
Enter the maximum capacity of the scale, total 5 digits
(f) ( g) ( h) ( i ) ( j )
For example:
30.000 kg
⇒
Key in 30000
300.0 kg
⇒
Key in 03000
NOTE 3
Set the division size and decimal point position to determine the display resolution
(k ) ( l) ( m )
(k)
⇒
Division size (select 1, 2, or 5)
(l)
⇒
The number of decimal places (0 ~ 5)
For example:
60.000 kg
⇒
enter 3
300.0 kg
⇒
enter 1
(m)
⇒
range setting (select one of parameters 0, 1, or 2)
For example:
0 &1
⇒
full range, 2
⇒
dual range(divided at 1/2 of the full scale)