W W W . P S S O . D E
25
Display LEDs
•
PROT
: protective circuit is active
•
CLIP
: overload
•
-10 dB, -5 dB
: input level indication
•
SIG
: signal indication
•
PARL
:
parallel operation
•
BRD
:
bridge operation
Level control
s
Standby indicator
Power indicator
Power on/off
Fuse holder
Only replace the fuse when the device is
disconnected from mains. Only use fuses of
the same rating and power. The correct fuse
value is specified on the rear panel.
Mains cable
For connection to a mains socket. If the
power voltage does not match the allowed
working voltage of 230 V ~, the power supply
will be automatically turned off.
DIP switches input sensitivity
0.775 V 1 V
32 dB
DIP switches operating mode
and soft clipping
• Switches 3 and 4 select the operating
mode:
Bridge
Parallel
Stereo
• Switches 1 and 2 influence the clipping
behavior:
soft limiting radical limiting
Input jacks
Balanced XLR inputs for connecting units
with line level.
Feed-through outputs
Balanced XLR outputs for connection of a
further amplifier.
Speaker connectors channel 1
• Screw terminals [
+
] and [
-
] for channel 1.
• Screw terminal [
+
] as positive terminal for
bridge operation.
Speaker connectors channel 2
• Screw terminals [
+
] and [
-
] for channel 2.
• Screw terminal [
+
] as negative terminal for
bridge operation.
Speaker connectors channel 1
Speaker jack for channel 1.
Speaker connectors channel 2
Speaker jack for channel 2.