Psion PowerScan M8300 series Скачать руководство пользователя страница 22

 

 

     

Psion Inc. 

2100 Meadowvale Boulevard, 

Mississauga, Ontario, Canada L5N 7J9 

 

     http://www.psion.com 

 08

 

 

dichiara che 

declares that the 

déclare que le 

bescheinigt, daß das Gerät 

declare que el 

 

 

PowerScan Mxxx; Cordless Bar code Reader 

 

 

e tutti i suoi modelli 

 

 

and all its models 

 

 

et tous ses modèles 

 

 

und seine Modelle 

 

 

y todos sus modelos 

 

 

sono conformi alle Direttive del Consiglio Europeo sottoelencate: 

are in conformity with the requirements of the European Council Directives listed below: 

sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: 

den nachstehenden angeführten Direktiven des Europäischen Rats: 

cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente: 

 

1999/5/EEC R&TTE

 

 

Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: 

This declaration is based upon compliance of the products to the following standards: 

Cette déclaration repose sur la conformité des produits aux normes suivantes: 

Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: 

Esta declaración se basa en el cumplimiento de los productos con la siguientes normas: 

 

ETSI

 

EN

 

301

 

489-3

 V

1.4.1,

 

A

UGUST 

2002

 

:

E

LECTROMAGNETIC COMPATIBILITY AND 

R

ADIO 

SPECTRUM 

M

ATTERS 

(ERM);

 

E

LECTROMAGNETIC 

COMPATIBILITY 

(EMC)

 STANDARD FOR RADIO 

EQUIPMENT AND SERVICES

;

 

P

ART 

3:

 

S

PECIFIC 

CONDITIONS FOR 

S

HORT

-R

ANGE 

D

EVICES 

(SRD)

 

OPERATING ON FREQUENCIES BETWEEN 

9

K

H

Z AND 

40GH

Z

 

 

ETSI

 

EN

 

300

 

220-3

 V

1.1.1,

 

S

EPTEMBER  

2000

 

E

LECTROMAGNETIC COMPATIBILITY AND 

R

ADIO 

SPECTRUM 

M

ATTERS 

(ERM);

 

S

HORT 

R

ANGE 

D

EVICES 

(SRD);

 

R

ADIO EQUIPMENT TO BE USED IN THE 

25MH

TO 

1000MH

Z FREQUENCY RANGE WITH POWER LEVELS 

RANGING UP TO 

500

M

W;

 

P

ART 

3:

 

H

ARMONIZED 

EN

 

COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 

3.2

 OF THE 

R&TTE

 

D

IRECTIVE 

 

EN

 

60950-1,

 

D

ECEMBER 

2001

 

INFORMATION TECHNOLOGY EQUIPMENT 

-

 

S

AFETY 

-

 

 

P

ART 

1

 

:

 

G

ENERAL 

R

EQUIREMENTS

 

 
 
 
 

 

April 16, 2008 

 

 

 

 
 

Содержание PowerScan M8300 series

Страница 1: ...PowerScan M8300 READERS QUICK REFERENCE GUIDE August 16 2011 PN 8000169 B ISO 9001 Certified Quality Management System...

Страница 2: ...whole or in part except for the sole purpose of assisting in proper use of Psion manufactured goods and services by their rightful own ers and users Any other use of this document is prohibited Discl...

Страница 3: ...n updates for this product are available on the Internet Log on to www psion com I Su Internet sono disponibili le versioni aggiornate di driver e docu mentazione di questo prodotto Questo manuale dis...

Страница 4: ...the maximum trace levels of lead cadmium mercury hexavalent chromium and flame retardants PBB and PBDE that may be contained in a product Only products meeting these high environmental standards may b...

Страница 5: ...com quickReferenceGuides Help_Desk_Contact_Numbers_A4 pdf Worldwide Offices Company Headquarters Psion Inc 2100 Meadowvale Boulevard Mississauga Ontario Canada L5N 7J9 Tel 1 905 813 9900 Fax 1 905 81...

Страница 6: ...NOTES...

Страница 7: ...0 laser readers automatically scan barcodes at a distance Simply aim and pull the trigger Scan Line Position Code scanning is performed along the scan line emitted from the reading window This line mu...

Страница 8: ...ch should be aimed over the code center to get the best reading performance see figure 1 above By completely pressing the trigger the scan line appears to start the code scanning 2 After setting up th...

Страница 9: ...or the C 8000 battery charger The Reader LED on the cradle battery charger turns red The battery is completely charged when the Reader LED on the cradle battery charger turns green To change the batte...

Страница 10: ...e BC 80X0 Configuration in the BC 80X0 Quick Reference or PowerScan M8300 BC 80X0 Stand Alone Configuration 1 Connect a BC 80X0 cradle to the Host For installation and connection information see the B...

Страница 11: ...rapidly configure your point to point application END OF PROCEDURE YOUR READER IS NOW READY TO READ CODES 1 Apply the bind address label onto the BC 80X0 base station as indicated in the BC 80X0 Crad...

Страница 12: ...eric code selection of steps 3 4 and 5 use the table at the end of this Quick Reference Guide 1 Restore PowerScan M8300 Default o 2 Enter Configuration 3 Set Date IA six digits for Day Month and Year...

Страница 13: ...ers to the same cradle see the following section Using Multiple Readers with Same Cradle Bind RN0 I The green LED on the PowerScan M8300 will blink the reader is ready to be positioned onto the cradle...

Страница 14: ...TAR MODEM Stand Alone Setup To configure a PowerScan M8300 reader to communicate with STAR Modem in Stand Alone Mode follow the PowerScan M8300 BC 80X0 Stand Alone Setup procedure substituting steps 6...

Страница 15: ...System devices such as Stargate RF base stations 1 Restore PowerScan M8300 Default o 2 Enter Configuration 3 Set Date IA six digits for Day Month and Year DDMMYY 4 Set Time IB four digits for Hours a...

Страница 16: ...the same area must have different addresses 7 Set First STAR System Address RSR four digits from the Numeric Table in the range 0000 to 1999 8 Set Last STAR System Address RTT four digits from the Num...

Страница 17: ...characters Standard Code 39 no check digit control variable length code 1 99 characters Code 128 variable length code 1 99 characters disabled codes EAN 128 ISBT128 Code 93 Codabar pharmaceutical cod...

Страница 18: ...solution 0 076 mm 3 mils 0 19 mm 7 5 mils PCS minimum Datalogic Test Chart 15 25 Scan Angle 42 13 5 0 7 Laser Safety Class 2 EN 60825 1 CDRH Radio Features European Models USA Models Radio Frequency 4...

Страница 19: ...5 24 2 cm 1 4 9 5 in 10 2 9 42 8 cm 1 1 16 8 in 13 2 3 55 1 cm 0 9 21 7 in 20 6 3 78 5 cm 2 5 30 9 in 40 2 5 97 8 cm 1 0 38 5 in mil Typical reading distance with good quality codes 7 5 18 50 cm 7 0...

Страница 20: ...PSION 14 PowerScan M8300 Numeric Table 01 0 12 1 23 2 34 3 45 4 56 5 67 6 78 7 89 8 9 9...

Страница 21: ...Numeric Table Quick Reference Guide 15 NOTES...

Страница 22: ...is based upon compliance of the products to the following standards Cette d claration repose sur la conformit des produits aux normes suivantes Diese Erkl rung basiert darauf da das Produkt den folge...

Отзывы: