CableMaster
CM400
Quick Start Guide
Testing:
A. Plug the wire into the correct Test Port, Ethernet to RJ45
B. Plug the opposite end into the Main Remote
C. Press Network Button
D. The LCD Display reports wire condition, Pass/Fail
E. To turn off, press O/ID Button
Toning:
A. With the unit turned OFF, hold down the TONE button until
LCD illuminates
B. To select a tone cadence, press the TONE button repeatedly to step through
the four cadence options: HI, LO, Hi-Lo1, and Hi-Lo1. Stop when you reach the
option you want. The option you select determines the cadence sent from the
main tester, through the cable, and picked up by the tone tracer probe.
C. Press the appropriate cable type button (voice, video, or data) to select a
cable for the tone signal
* Note: Tone is detected by a tone tracer probe
Features:
Testing: CM400 shows Opens, Shorts, Miswires, Split Pairs, PASS and
FAIL results quickly.
Toning: CM400’s built-in tone generator is a fl exible and function-packed
tone generator. Its confi gurable signal can be generated to fi nd and fi x the
position on any type of cable - either exposed or hidden, in ceilings or
behind walls.
Option: CM400 is supported by (1-19) wiremapping ID locators (Network/Coax).
Button Function
1. LCD Display
2. Voice Mode
3. Video Mode
4. Data Mode
1
4
3
6
7
5
2
5. Tone Mode
6. On/Off and ID Mode
7. Main Unit Remote