4.2 COM BSS
Menu selection
Choose ‘COM’ in the menu and press ‘OFF’
Tester automatically begins to identify the alternator control system
After, press ‘Mode’ for Generator Test
System
COM BSS_1
Connection (A)
COM (output / Input)
A.
3.
1. Field duty cycle
Increase as high as possible by activating the car accessories
2. Voltage output
Pass when it’s close to the set voltage (
+/- 0,4V deviation
)
3. Voltage set-point
Voltage can be changed by pressing buttons 12,5V / 13,5V / 15,5V / OFF
(
With low load only!
)
4. Pass
Error
Pass = If you can change VSP / No message
Error = Mechanical / Electrical / Temperature / VSP doesn’t change
1.
1.
2.
2.
In some cases when testing BSS protocols, after the VC-11R identifies the protocol it starts to „lose” the
identification and tries to identify it again and again. When this happens, you have to press 13,5 and 15,5
buttons simultaneously, what puts the tester into manual mode, allowing you to continue the test.
It happens because the signal contains not only data for alternators, but also some „useless” information
that can interfere with the tester.