background image

V2550 PLASTIC - HORIZONTAL

V2550 PLASTIC

A2550V PLASTIC

MATERIAL

DIAPHRAGMS

 (2)

DIAPHRAGM 

BACK-UP 

SEAL

(2)

POLY BALL 

CHECK 

CARTRIDGE

(4)

PVDF BALL 

CHECK 

CARTRIDGE

(4)

MANIFOLD 

O-RINGS

(4)

PTFE 

00-1044-55

00-9189-55

00-9188-55

Sanifl ex™

00-1074-56

Wil-Flex™

00-1044-58

00-9189-58

00-9188-58

38-1371-58

PTFE-Encapsulated FKM

38-1371-60

LW0356 Rev. F

P A R T S   L I S T I N G

E X P L O D E D   V I E W

D I S A S S E M B L Y   /   R E A S S E M B L Y

E L A S T O M E R   O P T I O N S

D I M E N S I O N A L   D R A W I N G

D I M E N S I O N A L   D R A W I N G

D I M E N S I O N A L   D R A W I N G

M A X I M U M   T O R Q U E   S P E C I F I C A T I O N S

Item

Description

Qty.

V2550

/PPPPE/…/P/N

A2550V

/PPPPA/…/P/N

V2550

/KKPPE/…/P/N

A2550V

/KKPPA/…/P/N

AIR DISTRIBUTION COMPONENTS

1

Air Valve Assembly

1

1

00-2044-99

00-2044-99

Air Valve Assembly, Solenoid

2

1

00-2014-99

00-2014-99

2

Gasket, Solenoid Valve

1

00-2640-56

00-2640-56

3

O-Ring, Shaft (-110, Ø.362" x Ø.103") 

2

15-2650-49

15-2650-49

4

Screw, Hex Washer Head Torx, Solenoid Air 

Valve (#4-24 x 1 1/4")

3

00-6134-03

00-6134-03

5

Center Section Assembly, Air Valve

3

1

00-3171-20

00-3171-20

Center Section Assembly, Accu-Flo

™4

1

00-3169-20

00-3169-20

6

Retaining Ring

1

00-2644-09

N/A

00-2644-09

N/A

7

Coil, 24V DC

1

00-2110-99-150

00-2110-99-150

Coil, 24V AC / 12V DC

1

00-2110-99-151

00-2110-99-151

Coil, 110V AC

1

00-2110-99-155

00-2110-99-155

8

Connector, Solenoid

1

00-2130-99

00-2130-99

9

Muffl er Element

1

00-3244-26

00-3244-26

10

Screw, Hex Washer Head Tri-Lobe (#10-14 x 1-1/4")

1

00-6114-03

00-6114-03

11

Muffl er, 1/4" MNPT

2

04-3240-07

04-3240-07

WETTED PATH COMPONENTS

12

Liquid Chamber

2

00-5014-20

00-5014-21

13

Manifold, Four Port, 1/4" (NPT)

1

00-5164-20

00-5164-21

14

Manifold Pipe Plug 1/4" (NPT)

2

00-7014-20

00-7014-21

10

Screw, Hex Washer Head Tri-Lobe (#10-14 x 1-1/4") 22

00-6114-03

BALL CHECK CARTRIDGE / MANIFOLD ORINGS

15

Ball Check Cartridge

4

*

*

16

Manifold O-Ring, TPE Fitted  (-214,  Ø.984 x Ø.139")

4

*

*

Manifold O-Ring, PTFE Fitted  (-214,  Ø.984 x Ø.139")

4

*

*

FULLSTROKE RUBBER / TPE / PTFE COMPONENTS

17

Shaft

1

00-3849-03

00-3849-03

18

Washer, Inner Piston (Ø.255" x Ø.468" x .060")

2

00-6844-03

19

Piston, Inner

2

00-3740-20

20

Diaphragm, Back-Up Seal PTFE only

2

*

21

Diaphragm, Primary

2

*

22

Piston, Outer

2

00-4640-20

00-4640-20

00-4640-21

00-4640-21

REMOVABLE FOOT COMPONENTS

23

Base, Removable Assembly

5

1

00-5540-99

24

Attachment Tab, Removable Base

1

00-5544-20

25

Screw, Slotted Hex Washer Head Tapping (#10-12 x 1/2") 1

00-6124-03

LW0356 Rev. F

ACCU-FLO™

W A R R A N T Y

22069 VAN BUREN STREET • GRAND TERRACE, CA  92313-5607

(909) 422-1700 • FAX (909) 783-3440

www.wildenpump.com

* See Elastomer Options
 

1

  Air Valve Assembly includes item 

6 and 9.

 

2  

Accu-Flo™ Air Valve Assembly 

includes items 2, 4, 7, 8 and 11.

ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS

DIMENSIONS

ITEM

METRIC 

(mm)

STANDARD 

(inch)

A

138

5.4

B

32

1.3

C

119

4.7

D

177

7.0

E

66

2.6

F

46

1.8

G

46

1.8

H

138

5.4

J

98

3.9

K

60

2.4

L

57

2.2

M

83

3.3

N

98

3.9

P

10

0.4

R

6

0.2

LW0351 REV. D

DIMENSIONS

ITEM

METRIC 

(mm)

STANDARD 

(inch)

A

138

5.4

B

34

1.3

C

60

2.4

D

99

3.9

E

125

4.9

F

145

5.7

G

148

5.8

H

76

3.0

J

11

0.4

K

103

4.1

L

172

6.8

M

98

3.9

N

60

2.4

P

57

2.2

R

83

3.3

S

98

3.9

T

10

0.4

U

6

0.2

LW0352 REV. C

VELOCITY MAXIMUM TORQUE SPECIFICATIONS

Description of Part

Torque

Liquid Chamber – Center Section (#10)

4.5 N•m (40 in-lb)

Outer Piston

5.6 N•m (50 in-lb)

Solenoid - Center Section (#4)

1.6 N•m (15 in-lb)

Tools Required:

• 

 5/16” Socket Wrench

• 

7/16” Socket Wrench

• 

Snap-Ring Pliers

CAUTION:

 Before any maintenance or repair is attempted, the 

compressed air line to the pump should be disconnected and all air 
pressure allowed to bleed from the pump.

1. 

 Insert the smaller end of the air valve 
assembly (item 1) into center section 
(item 5) until fully seated. Install 
retaining ring (item 6) in groove on air 
valve assembly.

2. 

 Install backup O-rings (item 20) on to 
surfaces of center section (item 5).

3. 

 Slide washer (item 18) and inner pistons 
(item 19) on to ends of shaft.

4. 

 Slide diaphragms (item 21) on to ends 
of shaft. 

5. 

 Install outer pistons (item 22) on to ends 
of shaft.  Tighten to specifi ed torque (50 
lb-in).  Over-tightening could damage 
outer piston.

6. 

 

Install four (4) ball check cartridges 
(item 15) into manifold (item 13). NOTE: 
The cartridges must be installed in 
correct orientation. Align grooves on 
cartridge with ribs in manifold. Cartridge will be fl ush with end of the manifold if installed correctly.

7. 

Install four (4) manifold O-rings (item 16) on to ends of manifold (item 13).

8. 

 Place upper screw boss in manifold (item 13) in-between the fl anges at the bottom of the center section 
(item 5).

9. 

 Place the center section-manifold assembly between two liquid chambers (item 12), taking care to align 
the large bore on liquid chamber over the diaphragm and the two (2) small bores over the manifold.

10. 

 Place in a vise and carefully press assembly together. Take care not to pinch or damage sealing O-rings.  
There should be a consistent 0.05” gap between the center section (item 5) and liquid chambers (item 
12).

11. 

 Fasten liquid chambers (item 12) to center section (item 5) and manifold (item 13) using (22) #10 screws 
(item 10).  Tighten fasteners to specifi ed torque (35 lb-in). Over-tightening fasteners could damage 
center section.

12. 

 Press muffl er element (item 9) into muffl er cavity (near air inlet) of center section (item 5). Hold muffl er 
element in place using one (1) #10 screw (item 10).

13. 

There are two mounting options for the base assembly (item 23). 

14. 

 Install one (1) NPT plug (item 14) into one (1) inlet port of the manifold (item 13). Install one (1) NPT plug 
into one (1) discharge port on manifold.

LW0355 REV. D

ITEM METRIC 

(mm)

STANDARD 

(inch)

A

138

5.4

B

32

1.3

C

108

4.3

D

143

5.6

E

201

7.9

F

5

0.2

G

116

4.6

H

78

3.1

J

46

1.8

K

46

1.8

ITEM METRIC 

(mm)

STANDARD 

(inch)

L

99

3.9

M

127

5.0

N

196

7.7

P

98

3.9

R

60

2.4

S

57

2.2

T

83

3.3

U

98

3.9

V

10

0.4

W

6

0.2

LW0353 REV. D

DIMENSIONS

 

3

  Air Valve Center Section Assembly includes items 

1, 6, 9 and 10.

 

4

  Accu-Flo™ Center Section Assembly includes 

items 1, 2, 3, 4, 7, 8, 11 and 17.

 

5

  Removable Base Assembly includes items 24 and 25.

Each and every product manufactured by Wilden Pump & Engineering, LLC is built 
to meet the highest standards of quality. Every pump is functionally tested to insure 
integrity of operation.  Wilden Pump & Engineering, LLC warrants that pumps, 
accessories and parts manufactured or supplied by it to be free from defects in 
material and workmanship for a period of fi ve (5) years from date of installation or 
six (6) years from date of manufacture, whichever comes first. Failure due to normal 
wear, misapplication, or abuse is, of course, excluded from this warranty.  Since 
the use of Wilden pumps and parts is beyond our control, we cannot guarantee 
the suitability of any pump or part for a particular application and Wilden Pump 
& Engineering, LLC shall not be liable for any consequential damage or expense 
arising from the use or misuse of its products on any application.  Responsibility 
is limited solely to replacement or repair of defective Wilden Pump & Engineering, 
LLC.  All decisions as to the cause of failure are the sole determination of Wilden 
Pump & Engineering, LLC.  Prior approval must be obtained from Wilden for 
return of any items for warranty consideration and must be accompanied by the 
appropriate MSDS for the product(s) involved. A Return Goods Tag, obtained from 
an authorized Wilden distributor, must be included with the items which must be 
shipped freight prepaid.  The foregoing warranty is exclusive and in lieu of all other 
warranties expressed or implied (whether written or oral) including all implied 
warranties of merchantability and fitness for any particular purpose. No distributor 
or other person is authorized to assume any liability or obligation for Wilden Pump 
& Engineering, LLC other than expressly provided herein.

   All boldface 

items are 

primary wear 

parts

.

WIL-41000-E-06

WIL-41000-E-06

WIL-41000-E-06

WIL-41000-E-06

WIL-41000-E-06

WIL-41000-E-06

WIL-41000-E-06

WIL-41000-E-06

Содержание Wilden A2550V Series

Страница 1: ...WS WIL FLEX Santoprene Three Black Dots VALVE BALLS TF PTFE White WF WIL FLEX Santoprene Three Black Dots VALVE SEAT K KYNAR P POLYPROPYLENE VALVE SEAT O RING TV PTFE ENCAP FKM WF WIL FLEX Santoprene SPECIALTY CODES 0150 Accu Flo 24V DC Coil 0151 Accu Flo 24V AC 12V Coil 0155 Accu Flo 110V AC Coil MODEL V2550 6 mm 1 4 VELOCITY A2550V 6 mm 1 4 ACCU FLO WETTED PARTS OUTER PISTON KK PVDF PVDF PP POLY...

Страница 2: ...s component materials in the Wilden Chemical Resistance Guide CAUTION Plastic series pumps are made from plastic that is not UV stabilized Direct sunlight exposure for prolonged periods can cause deterioration of plastic CAUTION V2550 pumps are not submersible CAUTION Always wear safety glasses when operating pump If diaphragm rupture occurs fluid being pumped may be forced out air exhaust WARNING...

Страница 3: ... O N A L D R A W I N G DIMENSIONS ITEM METRIC mm STANDARD inch A 138 5 4 B 32 1 3 C 119 4 7 D 177 7 0 E 66 2 6 F 46 1 8 G 46 1 8 H 138 5 4 J 98 3 9 K 60 2 4 L 57 2 2 M 83 3 3 N 98 3 9 P 10 0 4 R 6 0 2 LW0351 REV D WIL 41000 E 06 ...

Страница 4: ...D R A W I N G DIMENSIONS ITEM METRIC mm STANDARD inch A 138 5 4 B 34 1 3 C 60 2 4 D 99 3 9 E 125 4 9 F 145 5 7 G 148 5 8 H 76 3 0 J 11 0 4 K 103 4 1 L 172 6 8 M 98 3 9 N 60 2 4 P 57 2 2 R 83 3 3 S 98 3 9 T 10 0 4 U 6 0 2 LW0352 REV C WIL 41000 E 06 ...

Страница 5: ... STANDARD inch A 138 5 4 B 32 1 3 C 108 4 3 D 143 5 6 E 201 7 9 F 5 0 2 G 116 4 6 H 78 3 1 J 46 1 8 K 46 1 8 ITEM METRIC mm STANDARD inch L 99 3 9 M 127 5 0 N 196 7 7 P 98 3 9 R 60 2 4 S 57 2 2 T 83 3 3 U 98 3 9 V 10 0 4 W 6 0 2 LW0353 REV D DIMENSIONS WIL 41000 E 06 ...

Страница 6: ...ax Flow Rate 21 6 lpm 5 7 gpm Max Size Solids 0 8 mm 1 32 1 Displacement per stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 1 bar 30 psig head pressure Example To pump 12 5 lpm 3 3 gpm against a discharge head of 2 1 bar 30 psig requires 4 1 bar 60 psig and 10 4 Nm3 h 6 1 scfm air consumption Caution Do not exceed 6 9 bar 100 psig air supply pressure WIL 41000 E 06 ...

Страница 7: ...s meant to be a guide only There are many variables which can affect the pump s operating characteristics Suction lift can be affected by the number of intake discharge elbows viscosity of pumping fluid elevation atmospheric pressure pipe friction losses and other factors Caution Do not exceed 6 9 bar 100 psig air supply pressure WIL 41000 E 06 ...

Страница 8: ...per Stroke1 0 04 L 0 01 gal Max Flow Rate 14 8 lpm 3 9 gpm Max Size Solids 0 8 mm 1 32 1 Displacement per stroke was calculated at 4 8 bar 70 psig air inlet pressure against a 2 1 bar 30 psig head pressure Example To pump 7 9 lpm 2 1 gpm against a discharge head of 2 1 bar 30 psig requires 4 1 bar 60 psig and 6 6 Nm3 h 3 9 scfm air consumption Caution Do not exceed 6 9 bar 100 psig air supply pres...

Страница 9: ... I O N This curve demonstrates the flow created when the stroke rate is varied under static air and fluid pressure conditions This curve can be applied to different pressure conditions to estimate the change in flow due to stroke rate WIL 41000 E 06 ...

Страница 10: ...mized unnecessary elbows bends and fittings should be avoided all in an effort to reduce friction losses The suction hose must be non collapsible If rigid piping is used it should be supported independently of the pump In addition the piping should be aligned to avoid placing stress on the pump fittings When used in self priming applications it is critical that all fittings and connections are air...

Страница 11: ...can swell and become stuck if not compatible with fluid pumped Replace if necessary Pump runs but little or no product flows 1 Check for cavitation Confirm vacuum required to lift the fluid is not greater than the vapor pressure of the fluid being pumped Slow pump speed to allow viscous fluids to flow into liquid chambers 2 Ensure that the suction lift requirement is within the pump model s capabi...

Страница 12: ... if installed correctly 7 Install four 4 manifold O rings item 16 on to ends of manifold item 13 8 Place upper screw boss in manifold item 13 in between the flanges at the bottom of the center section item 5 9 Place the center section manifold assembly between two liquid chambers item 12 taking care to align the large bore on liquid chamber over the diaphragm and the two 2 small bores over the man...

Страница 13: ...E X P L O D E D V I E W ACCU FLO ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS LW0355 REV D WIL 41000 E 06 ...

Страница 14: ...014 20 00 5014 21 13 Manifold Four Port 1 4 NPT 1 00 5164 20 00 5164 21 14 Manifold Pipe Plug 1 4 NPT 2 00 7014 20 00 7014 21 10 Screw Hex Washer Head Tri Lobe 10 14 x 1 1 4 22 00 6114 03 BALL CHECK CARTRIDGE MANIFOLD O RINGS 15 Ball Check Cartridge 4 16 Manifold O Ring TPE Fitted 214 Ø 984 x Ø 139 4 Manifold O Ring PTFE Fitted 214 Ø 984 x Ø 139 4 FULL STROKE RUBBER TPE PTFE COMPONENTS 17 Shaft 1 ...

Страница 15: ... Flex 00 1044 58 00 9189 58 00 9188 58 38 1371 58 PTFE Encapsulated FKM 38 1371 60 LW0356 Rev F E L A S T O M E R O P T I O N S M A X I M U M T O R Q U E S P E C I F I C AT I O N S VELOCITY MAXIMUM TORQUE SPECIFICATIONS Description of Part Torque Liquid Chamber Center Section 10 4 5 N m 40 in lb Outer Piston 5 6 N m 50 in lb Solenoid Center Section 4 1 6 N m 15 in lb WIL 41000 E 06 ...

Страница 16: ...mp Engineering LLC shall not be liable for any consequential damage or expense arising from the use or misuse of its products on any application Responsibility is limited solely to replacement or repair of defective Wilden Pump Engineering LLC All decisions as to the cause of failure are the sole determination of Wilden Pump Engineering LLC Prior approval must be obtained from Wilden for return of...

Отзывы: