background image

INSTALLATION

OPERATION

MAINTENANCE

S6C - S6C HP PUMPS

INSTRUCTIONS 1002-C00 e

Section

1002

Effective

November 2011

Replaces

October 2010

Original instructions

Your distributor :

Z.I. La Plaine des Isles - F 89000 AUXERRE - FRANCE

Tel. : +33 (0)3.86.49.86.30 -  Fax : +33 (0)3.86.49.87.17

[email protected]  -  www.mouvex.com

3, Poruchik Nedelcho Bonchev Str., fl. 5,1528 Sofia, Bulgaria

tel: +359 2 973 27 67

e-mail: [email protected]

Содержание MOUVEX S6C

Страница 1: ...ember 2011 Replaces October 2010 Original instructions Your distributor Z I La Plaine des Isles F 89000 AUXERRE FRANCE Tel 33 0 3 86 49 86 30 Fax 33 0 3 86 49 87 17 contact mouvex com www mouvex com 3 Poruchik Nedelcho Bonchev Str fl 5 1528 Sofia Bulgaria tel 359 2 973 27 67 e mail office daisglobal eu ...

Страница 2: ...g 0 6 bara maximum 3 0 barg 4 0 bara Acceptable maximal differential pressure S6C 6 bar S6C HP 10 bar Cylinder capacity S6C 0 370 liter rev S6C HP 0 206 liter rev When the pump works with an inlet gauge pressure less than zero the maximum outlet pressure will be calculated as if the inlet pressure is equal to zero This is a SAFETYALERT SYMBOL When you see this symbol on the product or in the manua...

Страница 3: ...NT 1002 C00 11 11 S6C S6C HP Pumps e 3 12 1 OVERALL DIMENSIONS Weight 62 kg Dimensions in millimetres POSITION OF THE ORIFICES Pump plate Orifices Connection Standards Suction 1 3 5 1 Discharge 1 to 8 5 ...

Страница 4: ...n will not damage the pump but it will not allow the unit to pump product 2 4 Protection of the installation In the case where valves are placed on the suction and discharge pipes make sure that they cannot be closed without prior stopping of the pump The pump must be protected against excess pressure It can be delivered with a pressure switch to ensure this function Also make sure that the pump a...

Страница 5: ...for angular misalignment see instructions of the coupling for authorised values The 3 figures below show in detail the operation and the possible defects Controlling the alignment at each stage of the installation is important to be sure that none of these stages have generated stresses on the unit or the pump after fastening on the foundations after fastening the pipes after the pump has been ope...

Страница 6: ...RNING Hazardous pressure can cause personal injury or property damage TAKE ALL NECESSARY MEASURES TO RENDER ANY START UP EVEN ACCIDEN TAL OF THE PUMP DURING THE WORK IMPOSSIBLE WARNING Any unforeseen start up can cause serious injuries or important material damages THE SURFACES CAN BE AT A TEMPERA TURE LIABLE TO CAUSE INJURY OR SEVERE DAMAGE CAUTION Excessive temperature can cause injury or severe...

Страница 7: ...le not to run the S Series pump during CIP although low speed 100 rpm is acceptable by alter nating start stop operation During CIP the S6C pump is flushed through Indeed the pressure at entry to the pump is higher than the exit pressure the piston lifts off from the cylinder and enables complete circulation of the cleaning liquid through the S6C pump see fig 2 Figure 2 CIP Pump S6C Pump IN NO CAS...

Страница 8: ...e prematu rely worn In the case of assembly in parallel discharge of the centrifuge pump to the discharge of the S6C pump the 2 pumps must never be run at the same time In this case the S6C pump cleans itself 4 4 Sterilisation In Place SIP The serie S pumps are perfectly adapted to all pro cesses using SIP Sterilisation In Place pump stopped maximum 20 mn per cycle 1 or 2 cycles per day Bypass cir...

Страница 9: ...SERVI CE OR MAINTENANCE CAN CAUSE PER SONAL INJURY OR PROPERTY DAMAGE CAUTION Hazardous pressure can cause personal injury or property damage BE CAREFUL WITH THE WEIGHT OF THE PARTS WHEN THEY ARE BEING REMOVED WARNING The weight ot the parts can be dangerous and may provoke bodily injuries or material damages DISCONNECTING THE FLUID OR PRESSU RE CONTAINMENT COMPONENTS DURING PUMP OPERATION CAN CAU...

Страница 10: ...block by screwing 2 M8 screws in the 2 diametrically opposed M8 internal threads in the transmission block flange so as to pro gressively eject the main body 101 5 4 Remounting the transmission block Proceed in the reverse order from the preceding chapter taking care to correctly orient the main body 101 All screws must be degreased and mounted with a medium thread locking adhesive LOCTITE 243 for...

Страница 11: ...ive maintenance schedule according to their own experience 6 2 Checking of seals Seals material are intended for use in normal conditions in food process In order to ensure a reliable sealing on S series pumps we recommend to do an inspection of the seals every three months this time could be shorter if using the pump in hard condi tions Contact the manufacturer for advice if necessary replace the...

Страница 12: ...EX Directive 94 9 EC 23 march 1994 as transposed by the national legislation concerning equipment intended to be used in explosive atmospheres Conformity obtained by application of the standards NF EN 1127 1 1997 NF EN 13463 1 2009 NF EN 13463 5 2009 ATEX Certification delivered by INERIS Notified Body INERIS Parc Technologique Alata 60550 Verneuil en Halatte France The equipment indicated above m...

Отзывы: