background image

 

Step 4.

 

Replace the right and left blower box panels 

(D)

  with  screws 

(E)

  (18X).  (Note:  If the 

blower box wasn’t already installed on the furnace, the missing screws (12X) can be 

found in the blower box user’s manual kit). 

 

Note:  To install the oil unit on the left side of the furnace, replace  Step 5 by  the  Section 

additional steps for left side installation

”. Continue the installation from Step 6. 

Step 5.

 

Install the deflector 

(H)

 on the oil unit with the screws 

(I)

 (4X) provided with it. Then 

install the bolts 

(J)

 (4X) in the nuts located on the oil unit combustion chamber. 

               

 

Содержание Caddy Series

Страница 1: ...sted for Canada and the United States by an accredited laboratory This manual is available for free download on the manufacturer s web site It is a copyrighted document Resale is strictly prohibited T...

Страница 2: ...oil unit on the left side but requires additional steps Please note that the installation on the furnace is carried out in an identical way for both Beckett and Riello units For electrical connections...

Страница 3: ...ed on the furnace 18X if the blower box was already installed on the furnace Keep the screws Note The duct support assembly location may differ depending on the chosen configuration when installing th...

Страница 4: ...the blower box user s manual kit Note To install the oil unit on the left side of the furnace replace Step 5 by the Section additional steps for left side installation Continue the installation from...

Страница 5: ...5 Step 6 Remove the vision tube cap Step 7 Slide the oil unit R in the furnace Step 8 Use the bolts F on each side of the oil unit to have it leveled...

Страница 6: ...6 Step 9 Cut and install the gasket T on the left panel S the right panel U and the air jacket panels V 2X of the furnace according to the following measurements...

Страница 7: ...For a left side installation see Additional steps for left side installation for directions on which sides to install the air jacket panels Step 11 Install the left panel S on the furnace Secure it wi...

Страница 8: ...8 Step 12 Install the gasket X on the oil unit combustion chamber cover Then install the right panel U with the screws C 11X removed from Step 1...

Страница 9: ...9 Step 13 Install 4 screws W on the right side panel to plug the holes Step 14 Install the burner AA Secure it with washers Y 3X and nuts Z 3X Beckett unit...

Страница 10: ...10 Install the burner BB Secure it with washers Y 3X and nuts Z 3X Riello unit Step 15 Install and secure the sealed vision cap CC with the set screw DD...

Страница 11: ...11 Step 16 Install the certification label EE on the air jacket panel Step 17 In order to access the power board remove the filter support assembly FF held in place with screws GG 9X if necessary...

Страница 12: ...Electrical connections section Step 19 Reinstall the filter support assembly FF on the blower box with screws GG 9X previously removed on Step 17 SECTION 2 ELECTRICAL CONNECTIONS BECKETT BURNER Step 1...

Страница 13: ...rimary control and pass them through the middle grommet of the blower box and connect the wires of the oil unit on the OIL terminal on the power board Detail 4 To facilitate connections the use of a j...

Страница 14: ...e the two blowers box knockout HH located on both sides of the blower box Detail 1 Install a grommet JJ or a connector not included Detail 2 Step 2 Remove the screw LL that holds the power board cover...

Страница 15: ...facilitate connections the use of a junction box is recommended It can be installed on the back of the furnace Use the following diagram for reference Refer to the wiring diagram for complete connect...

Страница 16: ...the support K with the existing screws L 2X located on the top of the combustion chamber Step 5 2 Unscrew the bolts M 12X washers N 12X and nuts O 12X located on the periphery of the combustion chamb...

Страница 17: ...flector H on the oil unit with the screws provided with it I 4X Then fasten the bolts J 4X to the nuts located on the oil unit combustion chamber Step 5 4 Secure air jacket panels V 2X using screws W...

Страница 18: ...UH CADDY RIELLO 40 F3 91 000 0 50 X 700W DELAVAN 0 60 GAL US H 2 27 L H 150 PSI 1035 kPa 1 3 1 2 5 87 BLOCKED VENT SWITCH A Blocked Vent Switch is mandatory for installation with an oil fired applian...

Страница 19: ...19 WIRING DIAGRAM BECKETT BURNER...

Страница 20: ...20 WIRING DIAGRAM RIELLO BURNER...

Отзывы: