18
Technical data – Oil unit
MODEL
BURNER
TYPE
BTU
INPUT
NOZZLE
FLOW
HEAD
STATIC
PLATE
PRESSURE
AT THE PUMP
H.P. FAN
MOTOR
TUBULATOR
ADJUSTMENT
AIR
ADJUSTMENT EFFICIENCY
UH–
CADDY
BECKETT
AFG
90,000
0.55 X 60
0
W
(DELAVAN)
0.55 GAL US/H
(2.08 L/H)
L2
YES
140 PSI
(965 kPa)
1/3
---
0/2
85%
UH–
CADDY
RIELLO 40
F3
91,000
0.50 X 70
0
W
(DELAVAN)
0.60 GAL US/H
(2.27 L/H)
---
---
150 PSI
(1035 kPa)
1/3
1
2.5
87%
BLOCKED VENT SWITCH
A Blocked Vent Switch is mandatory for installation with an oil-fired
appliance that normally operates with its vent system under a negative
pressure. This device is intended to detect a blocked vent system,
responds to hot flue gases backing up through its heat transfer tube,
and can be wired to shut off the oil burner. It requires manual resetting.
Содержание Caddy Series
Страница 19: ...19 WIRING DIAGRAM BECKETT BURNER...
Страница 20: ...20 WIRING DIAGRAM RIELLO BURNER...