FURNACE PERFORMANCE

(1)

 

Fuel type 

Dry cordwood  

Recommended heating area[*] 

1,000 to 2,500 ft² (93 à 232 m²) 

Firebox volume 

3.6 ft³ (0.102 m³)  

Maximum burn time[*] 

10 h 

Maximum input capacity (dry cordwood)

(2)

 

310,000 BTU 

Overall heat output rate (min. to max.)

(3)

 

19,354 BTU/h to 47,052 BTU/h (5.6 kW to 13.8 kW) 

Average overall efficiency

(8)

 

76.6% (HHV)

(5)

 

82.0% (LHV)

(6)

 

Delivered heat output rate (min. to max.)

(7)

 

13,297 BTU/h to 42,234 BTU/h (3.9 kW to 12.4 kW) 

Average delivered efficiency

(4)

 

60.7% (HHV)

(5)

 

65.0% (LHV)

(6)

 

Optimum overall efficiency

(9)

 

83.2% 

Optimum heat transfer efficiency 

(14)

 

81%

 

Average particulate emissions rate

(10)(11)

 

0.095 lb/mmBTU (0.041 g/MJ)  

Average CO

(12)

 

8.78 lb/mmBTU (3.78 g/MJ) 

Average electrical power consumption

(13)

 

30 W  

[*] 

Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, 

climate, fuel type and other variables. The recommended heating area for a given appliance is defined by the manufacturer as its 
capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat 
distribution systems have a significant impact in making heat circulation optimum. 

 

(1)

  Values are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume, maximum burn time and 

maximum input capacity. Performances based on a fuel load prescribed by the standard at 10 lb/ft³ and with moisture content 
between 18% and 28%. 

(2) 

Input value at 10lb/ft³ fuel loading density and dry energy value of 8,600BTU/lb. 

(3) 

Overall: Radiated and delivered heat together at10lb/ft³ fuel loading density over one total burn cycle.

 

(4) 

Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand.

 

(5) 

Higher Heating Value of the fuel.

 

(6) 

Lower Heating Value of the fuel.

 

 

(7) 

Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one total burn cycle.

 

(8) 

Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.

 

(9)

 

Optimum overall efficiency at a specific burn rate (LHV).

 

 

(10) 

Based on delivered heat output. 

 

(11) 

This appliance is officially tested and certified by an independent agency. 

 

(12) 

Carbon Monoxide. Based on overall heat output at 10lb/ft³ fuel loading density.

 

(13) 

Unless st

ated otherwise, measures were taken directly at the main power source and include all electrical components present in 

the appliance.

 

(14) 

The  optimum  heat  transfer  efficiency  is  for  the  low  burn  rate  and  represents  the  appliance’s  ability  to  convert  the  energy   
contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical 
losses during combustion. 

 

 

Содержание CADDY ADVANCED PF01020

Страница 1: ...nace will provide years of comfort and safe operation Please keep this document Verified and tested for Canada by an accredited laboratory This manual is available for free download on the manufacture...

Страница 2: ...2...

Страница 3: ...NIMUM CLEARANCES TO COMBUSTIBLES MATERIALS FOR AIR RETURN DUCT 24 14 2 MINIMUM CLEARANCES TO COMBUSTIBLES MATERIALS FOR HOT AIR PLENUM 24 14 3 FLOOR PROTECTION 24 14 4 INSTALLING THE CONNECTING DUCT F...

Страница 4: ...RN CYCLE TIMES 41 17 2 PROLONGED POWER OUTAGE 41 18 FURNACE MAINTENANCE 42 18 1 ASH REMOVAL 42 18 2 CLEANING DOOR GLASS 43 18 3 DOOR ADJUSTMENT 43 18 4 REPLACEMENT OF THE GLASS AND GASKETS 44 18 5 CLE...

Страница 5: ...optimize comfort and reduce emissions with minimal maintenance This model meets the emissions limits of CSA B415 1 10 Standard and EPA 40CFR Part 60 subpart QQQQ 2020 limit To optimize the efficiency...

Страница 6: ...e maximum burn time and maximum input capacity Performances based on a fuel load prescribed by the standard at 10 lb ft and with moisture content between 18 and 28 2 Input value at 10lb ft fuel loadin...

Страница 7: ...nsions Width x Depth x Height included with optional blower assembly 14 in x 25 in x 1 in 356 mm x 635 mm x 25 mm Filter quantity 1 Particulate emission standard CSA B415 1 10 Canadian standard safety...

Страница 8: ...he control board housing recommended service clearance Clearance side wall 6 in Clearance side wall 24 in recommended service clearance Clearances ducts 6 in for the first 6 feet and 1 in after Cleara...

Страница 9: ...9 5 LABELS...

Страница 10: ...10...

Страница 11: ...11 6 TECHNICAL DATA OF THE CADDY ADVANCED ADD ON SERIE MODEL VARIABLE TEMPERATURE STATIC PRESSURE CADDY ADVANCED ADD ON SERIAL INSTALLATION F MIN MAX H2O 55 0 2 0 5 7 CADDY ADVANCED ADD ON DIMENSIONS...

Страница 12: ...D TO THE APPLIANCE ALWAYS OVERRIDES THE INFORMATION PUBLISHED IN ANY OTHER MEDIA OWNER S MANUAL CATALOGUES FLYERS MAGAZINES OR WEB SITES 9 1 GENERAL REQUIREMENTS Make sure the chimney outlet and the p...

Страница 13: ...ups within the system Prepare an emergency procedure in case of a chimney fire It is recommended to clean the heat exchangers thoroughly at the end of season in order to prevent corrosion 9 5 SMOKE DE...

Страница 14: ...ts from spilling smoke into the house The indications used to determine if an additional fresh air supply is necessary are not appropriate for all the situations When in doubt it is recommended to ins...

Страница 15: ...h and beech are slower growing and longer lived than softer woods like poplar and birch That makes hardwood trees more valuable The advice that only hardwoods are good to burn is outdated Old leaky ca...

Страница 16: ...e or even two years to dry fully especially if the pieces are big Firewood dries more quickly when stacked in the open where it is exposed to sun and wind it takes much longer to dry when stacked in a...

Страница 17: ...17 INSTALLATION AND OPERATION INSTRUCTIONS CADDY ADVANCED SERIAL ADD ON INSTALLATION PF01020...

Страница 18: ...OWING THROUGH THE BLOWER MOTOR SHALL NOT EXCEED THE NAME PLATE RATING 13 APPLIANCE INSTALLATION If the existing furnace must be modified the following standards must be respected Wood oil CSA B 139 In...

Страница 19: ...19 Option 1 Option 2 Minimum duct size 190 square inches 0 12 m2 R Minimum radius 6 inches...

Страница 20: ...20 Option 3 Option 4...

Отзывы: