ELECTRIC COMPONENTS INSTALLATION
All the wires joining the electric components must have the proper length. Run the wires connecting the
servo-motor to the relay-transformer away from surfaces that may get hot (see figure #1).
FAN LIMIT INSTALLATION ON PSG UH -CADDY MODELS
The wood fan limit control must be installed with the mounting bracket, in the warm air plenum on the left
hand side of the appliance; four holes are pre-drilled on the edge to match the holes on the mounting
bracket (see fig. #3).
Use the front holes on the Caddy.
The fan limit control for the oil unit (affixed to the junction box and relay-transformer, see figure #2) must
be installed on the lower left hand side removable panel, near the oil flue outlet; a 1" diameter hole is pre-
punched to allow the insertion of the fan limit’s sensor).
FIGURE #1
FIGURE #2
SERVO-MOTOR
RELAY
TRANSFORMER