WIL-10090-E-08
Wilden
®
17
Disassembly / Reassembly
Air Valve / Center Section Disassembly
Tools Required:
•
5/32" Hex Head
Wrench
•
O-ring Pick
CAUTION:
Before any maintenance or repair is attempted, the compressed air line to the pump
should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake,
discharge, and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into
a suitable container. Be aware of hazardous effects of contact with your process fluid.
The P.025 plastic utilizes a revolutionary Pro-Flo
®
air distribution system. A 3 mm (1/8”) air inlet
connects the air supply to the center section. Proprietary composite seals reduce the coefficient of
friction and allow the P.025 to run lube-free. Constructed of Acetal or polypropylene, the Pro-Flo air
distribution system is designed to perform in on/off, non-freezing, non-stalling, tough duty applications.
NOTE:
Replace worn parts with genuine Wilden parts for reliable performance.
Step 1
Remove air valve screws from center
section with a 5/32" hex- head wrench.
Step 2
Take care while removing air valve not
to damage gasket.
NOTE:
Air valve has molded-in
alignment pins for proper
positioning during assembly.
Step 3
Remove air valve end cap by simply
pulling it away from air valve body (no
tools required). Inspect O-ring and replace
as needed with genuine Wilden parts.
Содержание WILDEN PRO-FLO P.025
Страница 1: ...EOM ENGINEERING OPERATION MAINTENANCE P 025 Clamped Plastic Pump WIL 10090 E 08 Where InnovationFlows...
Страница 22: ...WIL 10090 E 08 Wilden 22 Exploded View and Parts Listing P 025 PLASTIC PTFE FITTED EXPLODED VIEW...
Страница 25: ...WIL 10090 E 08 Wilden Notes...
Страница 26: ...WIL 10090 E 08 Wilden Notes...