ALF-12030-E-02
All-Flo
14
REPAIR AND ASSEMBLY
PUMP WET END REMOVAL
STEP 1
Using the 7/16 inch wrench
remove four “Hex-Head Cap
Screws (1/4”-20 x 1-3/4”)” and
four “Flat Washers (1/4”)” from
the “Discharge Manifold”
STEP 2
Remove the “Discharge Manifold”.
STEP 3
Remove the “O-Ring”, “Valve Seat”
and “Ball” from the “Discharge
Manifold”.
TOOLS NEEDED
1) One Wrench,
7
/
16
Inch
2) Two Wrenches, ½ Inch
3) Two Wrenches, ¾ Inch
4) One Screwdriver, Slotted Head
WARNING
Prior to servicing the pump, ensure that the air
and fluid lines are closed and disconnected. While wearing personal
protective equipment, flush, drain and process liquid from the
pump in a safe manner.
WARNING
Maintenance must not be performed when a hazardous
atmosphere is present.
WARNING
For pump models with non-metallic manifolds, air valves, or
chambers: When the relative humidity in the surrounding atmosphere is above
30%, the equipment must not be touched by personnel unless first wiped down
with a damp cloth.
STEP 4
Using the 7/16 inch wrench re-
move four “Hex-Head Cap Screws
(1/4”-20 x 1-3/4”)” and four “Flat
Washers (1/4”)” from the “Suction
Manifold”.
STEP 5
Remove the “Suction Manifold”.
STEP 6
Remove the “O-Ring”, “Valve
Seat” and “Ball” from the “Suction
Manifold”.
7
SECTION