Disassembly / Reassembly
Step 10
After clamp bands are removed, pull liquid chambers apart.
Step 11
Remove tee section from liquid chamber and inspect o-rings for
signs of wear. Replace worn parts with genuine Wilden parts for
reliable performance.
Step 12
Using two 1” sockets, remove diaphragm
assembly from center section assembly.
Step 13
To remove the remaining diaphragm
assembly from the shaft, secure shaft with
soft jaws (a vise fitted with plywood or other
suitable material) to ensure shaft is not
nicked, scratched, or gouged. Using hands
or an adjustable wrench, remove
diaphragm assembly from shaft. Inspect all
parts for wear and replace with genuine
Wilden parts if necessary.
Step 14
Inspect diaphragms, outer and inner pistons
and disc spring (not shown) for signs of
wear. Replace with genuine Wilden parts if
necessary.
.