WIL-10070-E-03
Wilden
®
10
PERFORMANCE
A2P PLASTIC
RUBBER-FITTED
Height ............................
356 mm (14.0”)
Width .............................
297 mm (11.7”)
Depth .............................
259 mm (10.2”)
Est. Ship Weight .....................................
Polypropylene 8 kg (18 lbs)
PVDF 10 kg (23 lbs)
Air Inlet....................................
6 mm (1/4”)
Inlet ........................................
25 mm (1”)
Outlet .......................................
25 mm (1”)
Suction Lift ...................
6.2 m Dry (20.4’)
9.0 m Wet (29.5’)
Disp. Per Stroke
1
............. 0.12 l (0.030 gal.)
Max. Flow Rate ............ 136 lpm (36 gpm)
Max. Size Solids ...................
3.2 mm (1/8”)
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2 bar (30 psig) head pressure.
Example:
To pump 75.7 lpm (20 gpm)
against a discharge pressure head of
2.6 bar (37 psig) requires 4.1 bar (60 psig)
and 40.8 Nm
3
/h (24 scfm) air consumption.
(See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump performance curve.
A2P PLASTIC
PTFE-FITTED
Height ............................
356 mm (14.0”)
Width .............................
297 mm (11.7”)
Depth .............................
259 mm (10.2”)
Est. Ship Weight .....................................
Polypropylene 8 kg (18 lbs)
PVDF 10 kg (23 lbs)
Air Inlet....................................
6 mm (1/4”)
Inlet ........................................
25 mm (1”)
Outlet .......................................
25 mm (1”)
Suction Lift ..................
5.2 m Dry ( 17.0’)
9.0 m Wet (29.5’)
Disp. Per Stroke
1
.............0.11 l (0.028 gal.)
Max. Flow Rate ............ 110 lpm (29 gpm)
Max. Size Solids ...................
3.2 mm (1/8”)
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure against
a 2 bar (30 psig) head pressure.
Example:
To pump 37.9 lpm (10 gpm)
against a discharge pressure head of
3.2 bar (48 psig) requires 4.1 bar (60 psig)
and 32.3 Nm
3
/h (19 scfm) air consumption.
(See dot on chart.).
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump performance curve.