background image

________________________________________________

Specifications

 

ELECTRICAL AND PEDICURE SPA COMPONENT

 

SPECIFICATIONS

 

All electrical connections MUST be made by a qualified, licensed electrician in accordance with Local & National

 

Electrical and Building Codes. A 110V-50/60 Hz, 15 Amp, GFCI protected grounded circuit MUST be used to

 

supply power to the Pedicure Spa. A dedicated circuit must be used with a GFCI. All wiring must conform to

 

National & Local Electrical Codes

.

 

WARNING: IT IS EXTREMELY IMPORTANT THAT THE FOOT SPA OPERATES WITH GFCI PROTECTION

 

VERY IMPORTANT Both back of chair and seat are adjustable. When both are at maximum positions one must

 

allow 18”(44cm) from back wall to foot spa. This minimum distance assures unobstructed recline. Failure to follow

 

this required dimension might damage your spa components and plumbing connections, which will void your

 

warranty.

 

PEDICURE SPA SPECIFICATIONS:

 

Construction: Marble composite, high gloss, acetone-proof gel coat.

 

Two (2) electro-mechanical knobs control the drain and whirlpool.

 

Electro-mechanically operated reclining, massaging, and sliding seat with hand held control.

 

One (1) pipe-less whirlpool jet. (Pipe-free technology)

 

Power drain (optional) or Gravity drain (no drain pump)

 

Extendable water spray positioned well above water line, air gap is accommodated with back-flow

 

prevention required by plumbing code

 

Armrest swing up / down.

 

SPECIFICATIONS

 

Spa Dimensions &

 

Weights

 

BRISA = 30

” (W) x 55” (L)

 

All Models fully 

reclined: 74” (L). With Manicure Tray Installed: 46” (W)

 

Empty Weight: ~ 200 lbs. Shipping Weight: ~ 260 lbs.

 

Pedicure Stool: 12” – 13”.

 

~ 4-5 US Gallon

 

120 VAC. at 85W 60Hz

 

24VDC, 2.5A x 5

 

Motor 

– 120V at 85W 60 Hz

 

Maximum vertical lift: 3ft . Flow rate 500 GPH @ floor level

 

Adjustable Stool Height

 

Spa Water Capacity

 

Jet Motor

 

Massage Motors,

 

Seat Sliding & Reclining

 

Discharge Pump

 

Power source

 

115 VAC, 60HZ. Power needed per spa chair = 6 Amp

 

One (1) electro-mechanical knob for the Whirlpool. Rated at 5A contact.

 

One (1) electro-mechanical knob for the Drain. Rated at 5A contact.

 

Electrical Switches

 

Plug & Play Installation

 

Installation should be made with connection at the external interface parts.

 

Please consult with your local plumber.

 

BRISA® Pedicure Spa is UL listed.

 

Safety

 

11

 

Содержание BRISA

Страница 1: ...fy the carrier at once and request an inspection DO NOT DISCARD THE SHIPPING BOX If you give the carrier a clear receipt for goods that have been damaged in transit you do so at your own risk and expe...

Страница 2: ...in optional 7 Gravity Drain No Drain Pump 8 Plumbing Flow Pattern for Power Drain 8 Plumbing Flow Pattern for Gravity Drain 9 HOT AND COLD WATER SUPPLY LINES 9 ELECTRICAL AND PEDICURE SPA COMPONENT SP...

Страница 3: ...TO REDUCE RISK OF INJURY DO NOT PERMIT CHILDREN TO USE THIS UNIT UNLESS THEY ARE CLOSELY SUPPERVISED AT ALL TIME LIRE LES INSTRUCTION DU FABRICANT AVANT DE METTRE EN MARCHE UTILISER SEULEMENT A L INTE...

Страница 4: ...age System 1 Head Rest 2 Chair Cushion with Massage 3 Massage Remote Control 4 Armrest Wood 5 Manicure Tray Optional 4 11 Flex Water Filler Spray Spout 12 Up Down Armrest 13 Tub Light 14 15 8 Jet On O...

Страница 5: ...5 _______________________________________________________Installation SPA to SPA RECOMMENDED CLEARANCE Wall Clearance Spa 1 Center line Spa 2 Center line 60 30 23 18 WALL...

Страница 6: ...Down Swinging Armrest Manicure tray up and down Back Rest 1 To set backrest up Lift up the backrest until a Click is heard Make sure the lever is locked before operating 2 To fold down backrest Lift u...

Страница 7: ...since debris from broken rubber seal might clog water mixer Failure to do so may void your Warranty 3 Backflow preventer Due to differences in construction lay out of your Salon and City s plumbing co...

Страница 8: ...Pump Plumbing Flow Pattern Power Drain Seat Back 1 2 ID Hot Water 1 1 2 pipe 1 1 4 pipe 1 2 ID Cold Water Back Shell Mounting Screws 5 5 26 Screws 2 5 Hot Cold water Inlet Back Flow Preventer Not Incl...

Страница 9: ...replacement spa chair 1 New construction Make sure to remove any and all debris and or dust from current hot cold water pipes before hooking up to spa Suggested direction to remove debris turn on wat...

Страница 10: ...N WITH POWER DRAIN PUMP OR GRAVITY DRAIN NO PUMP Using schedule 40 PVC Power Drain or 1 flex tube Gravity Drain and appropriate traps Connect drain to meet local plumbing codes Rubber connection to th...

Страница 11: ...control the drain and whirlpool Electro mechanically operated reclining massaging and sliding seat with hand held control One 1 pipe less whirlpool jet Pipe free technology Power drain optional or Gr...

Страница 12: ...rn ON the DRAIN PUMP KNOB unless adequate water is in the tub THE WARRANTY IS VOID IF THE PUMP HAS BEEN RUNNING DRY NOTE Whirlpool action can cause even small amounts of soap or body oil to foam exces...

Страница 13: ...______________________________________________Operation and Care MAGNETIC JET COVER REMOVAL INSTALLATION 1 Turn Counterclockwise to remove Turn Clockwise to install 13...

Страница 14: ...______________________________________________Operation and Care JET HOUSING REMOVAL INSTALLATION 1 Turn clockwise to remove motor Turn counterclockwise to install motor 14...

Страница 15: ...duration of 15min 2 Press any button Rolling Spot Kneading Tapping Combine to enter Manual mode 3 Press Rolling Spot to stop rolling up down and stop at desired spot 4 Press Intensity button to select...

Страница 16: ...rews from bottom base Using the provided stand off blocks to adjust the height of seat frame as needed to allow seat frame to travel freely Install seat cushion with 2 screw Knobs Lever the back massa...

Страница 17: ...l be removed from the spa basin 2 The spa basin must be cleaned with soap or detergent and water 3 The spa basin must be disinfected with an EPA registered disinfectant with demonstrated bactericidal...

Страница 18: ...INSTALLATION ACCORDING TO THIS MANUAL IS REQUIRED FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY AND OR WARRANTY WILL BE NULL YOU MUST HAVE A QUALIFIED LICENSED PLUMBER TO CONNECT THE SPA IN PLACE SAFE...

Страница 19: ...Service Department 7171 Fenwick Lane Westminster CA 92683 USA Customer Service 888 213 7728 FAX 714 908 7694 www prospadepot com LENGTH OF WARRANTY Twelve 12 months starting from the date of shipment...

Отзывы: