![PS Audio Power Plant P300 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/ps-audio/power-plant-p300/power-plant-p300_operating-instructions-manual_1622085005.webp)
My turntable or fan based equipment is
not operating normally
Any turntable or equipment with AC
synchronous fans should not be used with
MultiWave II. These products must be used
with 60Hz SINE mode.
The P300 shut down, the display is blank
and the fuses are not blown
If airflow is inadequate or room temperature
is very warm and the P300 is run near 100%
capacity for very long periods of time this
type of shut-down may occur. If this occurs
the load should be lessened on the P300 or
else improve the airflow around the P300.
How do I reset the settings to factory
default?
To revert to the default factory settings.
Simply switch the P300 off at the back
panel. The default settings are: Sin mode,
60hz, 117v (export - 220v, Japan - 100v).
Specifications
Output:
Power
-
300 Watts
Voltage
-
95-240 Vts
Frequency
-
50-120 Hz
(depending on model)
Current
-
2 Amps
Peak
-
3 Amps
Distortion (THD)
-
0.1%
Input:
AC input range
-
90-250Volts
(depending on model)
Frequency input
-
50/60 Hz
Input capacity
-
750 VA
Power consumption
-
15 Watts
(with no load)
General:
Width
-
9 in
Height
-
5.5 in
Depth
-
19 in
Weight
-
30 lbs
Cooling system
-
forced
convection
7