background image

ZONE

D

AMPER

3

COM

COM

24V

24V

A

C

Mounting Panel

Selecting Transformer

Installing Dampers

Wiring Dampers

Remove the top cover and attach the panel to a wall close to 
the unit using four #8 screws.

The VA rating of the transformer depends on the number of 
actuators being used. The table below shows the VA required 
for each zoning component including the ProR80J dampers.

One or more dampers can be used to define a zone.  Dampers 
should be installed in the duct or ducts and sealed to insure no 
air leakage.  Shown below is the ProR80J-XX damper. 

The dampers are connected to the zoning panel with the cables 
provided with each damper.

The table below shows the number of dampers that can be 
used with a 3 -zone installation using a 40, 60 or 75VA 
transformer and ProR80J dampers.

Install the 24VAC transformer according to local electrical 
codes and connect the 24VAC output to the terminals on the 
panel using 2-conductor, 18 gage, thermostat wire as shown 
below.

1.

2.

3.

4.

HVAC

PANEL

ZONE DAMPERS

1

1

2

2

3

FAD

3

THERMOST

ATS

Q

u

ic

V

ie

w

ProC332J Zoning Panel

ProZone

Two #8 screws

Two #8 screws

Panel

3-Zone

Maximum VA

40VA Transformer 60VA Transformer 75VA Transformer

10VA

11 Dampers

19 Dampers

26 Dampers

1.8VA

2.4VA

Typical VA

10VA

1.0VA

1.0VA

Zone Thermostat

Zone Damper

Line

24VAC

2-conductor, 18 gage

Thermostat Wire

Zoning Panel

25-foot RJ12 cable
supplied with damper.

Plug damper cable into the
Zone Damper connector on
the zoning panel.

Daisy chained dampers
when more than one
damper required to
configure a zone.

AIRFLOW

Model ProR80J-008

ProZone

In

te

lli

ge

nt 

Zo

ni

ng

IN

OUT

Model A80-MJ

Modulating Position

Damper Actuator

24VAC, 2.2VA

Made in USA

ProZone

IN

OUT

Model A80-MJ

Modulating Position

Damper Actuator

24VAC, 2.2VA

Made in USA

ProZone

3

Содержание ProC232J

Страница 1: ...umps Selected using the PDMi3 plug in programming display module See table below See table below See table below HVAC PANEL ZONE DAMPERS 1 1 2 2 3 Fresh Air 3 THERMOSTATS Quick View Zoning Panel ProZo...

Страница 2: ...the plenum or freezing the indoor coil Color coded terminals for heat cool or heat pump thermostat Thermostat type selected using the PDMi3 Use 24VAC powered or battery powered thermostats VAC termina...

Страница 3: ...stall the 24VAC transformer according to local electrical codes and connect the 24VAC output to the terminals on the panel using 2 conductor 18 gage thermostat wire as shown below 1 2 3 4 HVAC PANEL Z...

Страница 4: ...heat pump thermostat should be used in Zone1 when heat pump equipment is selected Wiring of a heat pump zone thermostat is shown below Thermostat R C OB W2 E Y1 G Zoning Panel Terminal Function 24VAC...

Страница 5: ...the red and white thermostat wires to the thermistor wires no polarity using the wirenuts 3 Push the wirenuts and wire into the cover and secure the cover with the screw 1 Connect the red and white th...

Страница 6: ...respond to the Zone1 thermostat When the occupant leaves the home they can set the switch to Vacant and only set the Zone1 thermostat Installing the Duct Pressure Sensor Drill a 3 8 inch diameter hol...

Страница 7: ...es or navigate Press the CANCEL to cancel settings and return to the main menu The panel is ready to operate and control the equipment selected The PDMi3 can be used to customize the panel clone it fr...

Страница 8: ...s Yes to set the number of stages of heating and cooling the fan operation the supply air temperature limits outdoor changeover temperature for dual fuel heat pumps and number of zones being used Pres...

Страница 9: ...T Aux Heating 1 Stages U D NEXT Fan Mode Gas N NEXT Htg Temp Lmt 160 U D NEXT Htg Temp Lmt 160 U D NEXT Clg Temp Lmt 45 U D NEXT Clg Temp Lmt 45 U D NEXT Total Zones 3 Used U D NEXT Total Zones 3 Used...

Страница 10: ...heat cool thermostat for that zone Press No to see other thermostats that can be used in that zone Press Up or Down to change the number of auxiliary heating stages Press NEXT to continue If a heat pu...

Страница 11: ...Y N Bypass Ext Baro Y N Bypass ZoneDmprs Y N Zone1 Htg 50 BP Pos U D NEXT Zone1 Clg 50 BP Pos U D NEXT Zone2 Htg 50 BP Pos U D NEXT Zone2 Clg 50 BP Pos U D NEXT Zone3 Htg 50 BP Pos U D NEXT Zone3 Clg...

Страница 12: ...N Fresh Air Off Y On N Off If the contractor has calculated the CFM for fresh air and sized the damper to operate for a number of minutes each hour the minutes can be directly entered The PDMi3 allows...

Страница 13: ...Down to set the weighted zones when low speed fan is activated In the example if the weighted demand is less than 2 0 DSBK is activated Press Next to continue to next menu selection Press Yes to selec...

Страница 14: ...ooling stage Press Yes to start a test of the heating system to insure discharge temperature is correct Press Next to start a test stage2 heating to insure discharge temperature is correct or return t...

Страница 15: ...select the letter or number Press NEXT to go to the next letter in the name Press SAVE to save the clone name Monitor HVAC Performance Y N LAT 122 Prs 0 55 BP Pos 35 NEXT Press Yes to display the leav...

Страница 16: ...una Hills CA 92653 949 916 0945 Fax 949 458 8502 www ProZone US com Limited 5 Year Warranty The 5 year warranty is limited to the repair or replacement of defective product due to parts failure or def...

Отзывы: