Zones
Heating and Cooling Stages
Rev F Jun 2015
Bypass Control
Optional Sensors
Panel Power
Warranty
Wiring
Humidity Rating
Temperature Ratings
Dampers per Zone
Compatible Equipment
Equipment Selection
The panel can be used with traditional mechanical barometric
dampers or by adjusting the closed position limit on each zone
damper.
Discharge air (Model TS2) and outdoor air temperature sensor
(Model TS3 can be used. A pressure sensor (Model PS2) can be
used to monitor duct pressure.
24VAC (18 to 30), 10VA
5-year warranty limited to repair or replacement of panel due to
defective material or workmanship.
Use 18 or 20 AWG solid thermostat wire.
5 to 90% RH non-condensing.
Shipping
o
o
o
o
-20 to 150 F (-29 to 66 C)
o
o
o
o
0 to 165 F (-32 to 74 C)
Operating
Multiple dampers may be used to configure a zone. The total
number of dampers that can be used depends on the VA
rating of the 24VAC transformer used. Up to six dampers can
be daisy chained to configure a zone.
All panels operate with gas/electric systems, conventional heat
pumps and dual fuel heat pumps.
Selected using the PDMi3 plug-in programming/display
module. See table below.
See table below.
See table below.
HVAC
PANEL
ZONE DAMPERS
1
1
2
2
3
Fresh
Air
3
THERMOSTATS
Q
u
ic
k
V
ie
w
Zoning Panel
ProZone
7-5/8 (193)
9-5/8 (244)
1-5/8 (41)
Compatible Dampers
The ProR80J-XX dampers with plug and play cables. Each
damper is supplied with a 25-foot cable.
Compatible Thermostats
Compatible Thermostat Types
When gas/electric equipment is selected, heat/cool thermostats
are used in all zones. When heat pump equipment is selected,
a heat pump or heat/cool thermostat may be used in Zone1
and heat/cool thermostats are used in all other zones. Wireless
thermostats can be used with the optional plug in wireless
radio, ISMR2
Single stage, 24VAC powered or battery powered thermostats.
Or, wireless thermostats, Models T200WZ or T500WZ.
Zone
Pro
I n t e l l i g e n t Z o n i n g
Installation Guide
ProC232J, ProC332J, ProC332JP and ProC300JX
Zones on Panel
Two
No
Two
Two
Two
One
No
One
No
One
Yes
Two
Two
Two
Two
Two
Two
Yes. Up to 6 zones.
Yes. Up to 6 zones.
Three
Three
Model ProC232J
Model ProC332J
Model ProC332JP
Expandable
Heating Stages
Compressor Stages
Cooling Stages
Auxiliary Heating Stages
PDM Display on Panel
Gas/Electric Equipment
Heat Pump Equipment