1  Application area / device features

1.1 Application area

The SOLAREG II ENERGY controllers are high-performance microprocessor-con-

trolled units for controlling the functions of solar thermal systems. The SOLAREG  II 

ENERGY perfectly controls solar power systems equipped with one collector and 

one storage tank. 
The controllers are designed for use in dry rooms as well as residential, business 

and commercial applications. Prior to commissioning the device, make sure to 

verify that the intended use complies with the applicable regulations. 

1.2 Device features

The SOLAREG II generation of controllers is equipped with the following features:

Intuitive operating menu with graphic symbols and four operating buttons

 

Adjustable values

 

Integrated operating hours counter for storage tank charging

 

Start function for systems equipped with tube collectors

 

Integrated energy yield measurement  

 

(optional, only in conjunction with the yield measurement set)
Solar circuit pump RPM controll or switching controll

 

Extensive functions for system monitoring that display symbols to indicate er-

 

rors and faults
Storage of all values even during a prolonged mains power supply outage

 

Various protective functions, such as system protection, collector protection, 

 

recooling and flow monitoring
Generous wiring space

 

Available accessories:

Temperature sensor PT1000

 

Yield measurement set (incl. tube sensor)

 

Sensor connection box

 

Immersion sleeves

 

2  Safety instructions

Always completely disconnect the device from the operating voltage before 

 

performing installation or wiring work on the electrical equipment. 

Never mix up the connections of the protective low voltage areas (sensor, flow 

sensor) with the 230V connections. Otherwise, the device will be destroyed. The 

device and the connected sensors may carry deadly voltages.
Solar power systems can reach high temperatures. Such temperatures pose a 

 

risk of burns! Exercise caution when installing the temperature sensors!
Mount the SOLAREG II controller in a position where it will not be subjected 

 

to excessive operating temperatures (> 50°C) by any external heat sources.For 

safety reasons, the system may only remain in manual operation for testing 

purposes. In this operating mode, the system does not monitor for maximum 

temperatures and sensor functions. If there is any recognisable damage to the 

controller, cables or the connected pumps and valves, the system must not be 

started. 

 

 

 

 

All installation and wiring 
work must only be carried 

out on the controller when the 
device is disconnected from the 
power supply. 
The SOLAREG II must only be 
connected and commissioned by 
qualified personnel. In doing so, 
the applicable safety regulations 
must be observed.

Содержание Solareg II ENERGY

Страница 1: ...Microcontroller controlled temperature difference controller for solar thermal systems Operatingmanual Solareg II ENERGY...

Страница 2: ...7 1 4 Tube collector or start function 11 7 2 Protective functions 11 7 2 1 Collector protection 11 7 2 2 Recooling Holiday function 11 7 2 3 System protection 12 7 3 Additional function 12 7 3 1 Ene...

Страница 3: ...ection recooling and flow monitoring Generous wiring space Available accessories Temperature sensor PT1000 Yield measurement set incl tube sensor Sensor connection box Immersion sleeves 2 Safety instr...

Страница 4: ...opened 3 2 Wall mounting The device is mounted on the marked points A drilling template is provided with the device Insert the Quick Info card provided with the device into the pocket provided on the...

Страница 5: ...ors 2 sensors are required the third sensor is optional Mounting wiring the temperature sensors Mount the sensors on the collector and the storage tank Ensure proper heat transfer and use heat conduct...

Страница 6: ...decreases continuously Scroll right Select Confirm Scroll right in the main menu Select a menu item Confirm a value change and store it 5 Menu structure 5 1 Info menu The following measured and yield...

Страница 7: ...fer ence 2 35K 3K min 100 12 Set the minimum pump capacity using the RPM control 100 RPM control off 30 100 100 40 C Switch on tem perature for the thermostat func tion 20 90 C 40 C dT 10 K Hysteresis...

Страница 8: ...f 1 On 0 Off 1 120 C Collector protection function 110 150 C 120 C 2 0 Recooling function only if the collector protection is on 0 Off 1 On 0 Off 3 40 C Recooling temperature 30 90 C 40 C 4 0 Tube col...

Страница 9: ...30V connections L Mains phase N Neutral conductor mains and outputs A1 Solar circuit pump switching output 1 A2 Switching output 2 Sensor connections S1 Collector sensor S2 Lower storage tank S3 Therm...

Страница 10: ...s place when under the preset temperature Basic Setup menu Display Meaning Value range Factory set ting Line Value 6 1 The cooling or thermostat function can also be selected 0 Off 1 Cooling 2 Heating...

Страница 11: ...ecooling Holiday function The collector protection function is only effective if the storage tank temperature is below the temperature limit 95 Therefore during the holiday period for exam ple the sto...

Страница 12: ...enu Display Meaning Value range Factory set ting Line Value 5 0 Switches on or off the energy yield measurement function 0 Off 1 On 0 Off 8 System monitoring If an error occurs the flashing symbol is...

Страница 13: ...ce sensor if necessary Flashing Short circuit in the sensor cable Check cable Defective sensor Check sensor resistance and replace sensor if nec essary Circulation error No flow Flashing Additional di...

Страница 14: ...ircuits Defect device Contact the supplier Outputs are not switched on Controller is in manual operation Exit Manual operation Switch on condition is not satisfied Wait until switch on condition is sa...

Страница 15: ...min according to EN 60730 DIN VDE 0631 IEC 60664 IEC Output Voltage Power switching output 230V 1A approx 230VAfor cos 0 7 1 0 Fuse protection Fine wire fuse 5 x 20mm 2A T 2 amperes delayed action fus...

Страница 16: ...eduction of price is excluded Warranty claims may only be submitted by the customer and are non transferable If a defect occurs during the warranty period please contact the supplier installer When re...

Отзывы: