3.3 Connections
Bear in mind the following points concerning the 230 V connections:
■
If the controller is wired directly into the mains, it must be possible to isolate
mains power by using a switch external to the controller.
The switch is not required if the main power supply is provided via a cable and
earthed mains plug.
The controllers are designed for use with 230 V/50 Hz mains power. Any pumps
■
to be connected must also be rated for use at this voltage!
All earth leads must be attached to the terminals marked "PE".
■
■
The neutral lead terminals (N) are connected electrically and are not switched!
The A1 output serves to supply the pump with 230 V AC. Function selection
■
is carried out using the terminal O1 and corresponding jumper setting: "ANA"
(analogue output) or "PWM" (PWM output). For pumps with analogue signal
control via a 0-10 V analogue signal and pumps with PWM control via a PWM
signal at a freq. of 2 kHz.
3.4 Temperature sensor connection
SOLAREG II BASIC HE devices use PT1000 precision platinum temperature sensors.
2 sensors are required, the third sensor is optional.
Mounting / wiring the temperature sensors:
■
Mount the sensors on the collector and storage tank. Ensure proper heat
transfer, using heat-conductive paste if necessary.
Cross-sections for cable extensions (shielded):
■
- Up to 15 m, 2 x 0.5 mm
2
- Up to 50 m, 2 x 0.75 mm
2
The shield is connected to earth (PE).
Temperature sensors are connected according to the system layout. You do
■
not need to observe polarity for the two wires when cabling temperature
sensors.
■
Sensor cables must be laid separately from 230 V wires.
Sensor collection boxes equipped with surge protection should be used for
■
collector sensors and cable extensions.
4 Short descriptions and device operation
4.1 Display layout
During actual operation,
only a selection
of these symbols will be shown – de-
pending on the current menu.
Currently active menu
◂
Current display assignment
◂
Current readings, times or controller
◂
states: here 59.6 °C.
Measuring point
◂
Controller state/messages
◂
Display symbols
All possible display symbols are
shown below.
ok?
hPa
start
%
stop
dTmin max
F