General 

 
Read the instruction manual with all the security advices and warnings 

before the initial use

 of the units 

in order to secure a safe and conventional use. Keep this document throughout the life time of the 
machine to be able to refer to the instructions. In case of resale, pass it on with the unit. 

 Overview 

 
All kardiomed® 530 units are available as a boosted version. Those units are equipped with special elements to make the 
units even more robust. Besides that the units offer more comfort.   
 

Unit 

Max. user weight 

Features 

motion boosted cycle 800 fit/ med 

200 kg 

different elements to boost 

motion boosted cross 800 fit/ med  
 

200 kg 

different elements to boost 

motion boosted body 800 fit/ med 
 

200 kg 

different elements to boost 

motion boosted relax 800 fit/ med 
 

250 kg 

Turnable seat, higher back rest, arm rest and different 
elements to boost 

motion boosted sprint 800 fit/ med  

250 kg 

different elements to boost 

 

 

Maintenance 

The required safety level can only be ensured by checking the unit regularly for damage and attrition. Damaged parts need 
to get replaced right away and the unit needs to get decommissioned until its repair.  
Check the unit visually before every use, but at least daily for damaged parts, loose connections and atypical noises. 
Depending on the usage but the latest after six months the unit has to get inspected intensely. All connections and weld 
seams need to get checked and the unit needs to get cleaned.  
Clean the devices with mild purifier and a wet cloth to get off aggressive sweat. Dry the device afterwards.

 

The use of 

spray bottles is not allowed; it has shown that the unit never dries at spots that can´t be reached easily, so that rust may 
occur. Pay attention that no liquids run into the monitor as it could destroy parts of the electronic.

  

If disinfection is required only use

 

acryl-des® disinfection cloths (see 

http://www.schuelke.com/

).  

The monitor is showing a sign for low battery voltage when the functioning of the machine cannot be guaranteed without 
electricity from the brake anymore. Exchange the 3AA batteries by loosening the monitor from the frame. Take out the 
two screws on the back of the monitor and open it. Please pay attention that insert the new batteries the right way 
around, note the signing. Dispose the batteries according to the provisions. There is a return obligation; the customer can 
choose to give the batteries to the local disposer or to the distributor free of charge.  
Only use original spare parts, therefore please contact us. 

Warning: Retorque of cranks and pedals 

After the first 10 hours in usage the cranks and pedals need to get retorquened.  
If  they  do  not  get  retightened,  damage  of  the  axis,  pedals  or  cranks  is  possible  and  the  warranty  will  not  cover  the 
resulting damage. 
 