Address/Baudrate
The address of the device can be changed with this parameter. This is important for bus
systems with multiple users. Furthermore there is the possibility to change the baudrate. Please
consider that all bus users must use the same baudrate but different addresses.
Parameter display
Main display:
The current measurement value and the set emissivity value are displayed.
The symbols show the status of the switching outputs.
By using the PAR-button
you get into the parameter level. The current measurement
value is displayed additionally so that the influence of the parameter change is visible
immediately (e.g. emissivity).