Fibre to SAS/SATA II RAID Subsystem
User Manual
81
5.5 System Controls
5.5.1 System Configuration
To set the RAID subsystem system configuration options, click the
System
Configuration
link under the
System Controls
menu. The System
Configurations screen will be shown. Set the desired system option as needed.
System Beeper Setting:
This option is used to Disable or Enable the system’s RAID controller alarm beeper.
Background Task Priority:
The Background Task Priority indicates how much time and system resource the RAID
controller devotes to a background task, such as a rebuild operation. The RAID
subsystem allows user to choose the background task priority (High 80%, Medium 50%,
Low 25%, and Ultra Low 5%) to balance between background task process and
Volume Set access. For high RAID subsystem performance, specify a low value.
JBOD/RAID Configuration:
The RAID subsystem supports JBOD and RAID configuration.