
Fibre to SAS/SATA II RAID Subsystem
User Manual
13
RAID 3
sector-stripes data across groups of drives, but one drive in the group is
dedicated for storing parity information. RAID 3 relies on the embedded ECC in each
sector for error detection. In the case of drive failure, data recovery is accomplished by
calculating the exclusive OR (XOR) of the information recorded on the remaining drives.
Records typically span all drives, which optimizes the disk transfer rate. Because each
I/O request accesses every drive in the array, RAID 3 arrays can satisfy only one I/O
request at a time. RAID 3 delivers the best performance for single-user, single-tasking
environments with long records. Synchronized-spindle drives are required for RAID 3
arrays in order to avoid performance degradation with short records. RAID 5 arrays with
small stripes can yield similar performance to RAID 3 arrays.
Under
RAID 5
parity information is distributed across all the drives. Since there is no
dedicated parity drive, all drives contain data and read operations can be overlapped on
every drive in the array. Write operations will typically access one data drive and one
parity drive. However, because different records store their parity on different drives,
write operations can usually be overlapped.
Dual-level RAID
achieves a balance between the increased data availability inherent in
RAID 1, RAID 3, RAID 5, or RAID 6 and the increased read performance inherent in disk
striping (RAID 0). These arrays are sometimes referred to as RAID 0+1 (1E), RAID 30,
RAID 50 or RAID 60.
Содержание EP-2243D-F4S3
Страница 1: ...Fibre to SAS SATA II RAID Subsystem User Manual Revision 1 2 ...
Страница 44: ...Fibre to SAS SATA II RAID Subsystem 44 User Manual ...
Страница 45: ...Fibre to SAS SATA II RAID Subsystem User Manual 45 ...
Страница 46: ...Fibre to SAS SATA II RAID Subsystem 46 User Manual ...
Страница 47: ...Fibre to SAS SATA II RAID Subsystem User Manual 47 ...
Страница 48: ...Fibre to SAS SATA II RAID Subsystem 48 User Manual ...
Страница 56: ...Fibre to SAS SATA II RAID Subsystem 56 User Manual ...