DP-503-F4A3 RAID SUBSYSTEM
76
Installation and User Manual
The Hardware Monitor Information provides the temperature and voltage levels of the RAID
subsystem. All items are also unchangeable. When the threshold values are exceeded, warning
messages will be indicated through the LCD, LED and alarm buzzer.
Item
Warning Condition
Controller Board Temperature
> 60 Celsius
HDD Temperature
> 60 Celsius
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.4V
Power 3.3V
< 3.0V or > 3.6V
DDR Supply V2.5V
< 2.25V or > 2.75V
CPU Core V1.3V
< 1.17V or > 1.43V
DDR Termination Power +1.25V
< 1.125V or > 1.375V
Содержание DP-503-F4A3
Страница 1: ...DP 503 F4A3 RAID Subsystem Installation and User Manual Revision 1 1 P N PW0020000000322...
Страница 35: ...DP 503 F4A3 RAID SUBSYSTEM Installation and User Manual 35...
Страница 36: ...DP 503 F4A3 RAID SUBSYSTEM 36 Installation and User Manual...
Страница 37: ...DP 503 F4A3 RAID SUBSYSTEM Installation and User Manual 37...
Страница 38: ...DP 503 F4A3 RAID SUBSYSTEM 38 Installation and User Manual...