8
Door lock connection
Door Lock Controlled with Internal Power
Note:
1. Electronic lock of Power -on -to -unlock type should be used.
2.
The door lock is limited to 12V, and holding current must be less than 250mA.
3. The door lock control is not timed from Exit Button(EB).
4. The
Unlock Mode
Parameter of Monitor must be set to 0 (by default).
Connect one lock
Connect two locks
Connect one lock
Connect two locks
Jumper position in
1-2
Jumper position in 1-2
BUS
PL
S1
+
S 2
+
S-
BUS
PL S1+ S2+ S -
*
EB
LOCK
*
EB
*
EB
2
nd
1
ST
LOCK
2
nd
1
ST
LOCK
Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according to the lock.
2. The jumper must be taken off before connecting.
3. Setup the
Unlock Mode
of Monitor for different lock types.
• Power -on -to -unlock type:Unlock Mode=0 (by default)
• Power -off -to -unlock type:Unlock Mode=1