8. Using the Separate Loops

1)Effect Loops

When the five series loops provided aren’t enough for your system, the separate loops can be used as additional series loops.
Connect the input signal (the output from the preceding series loop, for example) to the IN jack, and connect the send jack (S-6,
S-7, or S-8) to the input of the effect unit. The output from the effect unit is then connected back to the corresponding PEC-2
return jack (R-6, R-7, or R-8), and the OUT jack is connected to the next loop or device.

2)Output Selector

This type of connection functions as an output selector, switching the input signal to one of two outputs. When the loop is on
“Output 1” is selected and “Output 2” is muted so that crosstalk and noise are eliminated. When the loop is off  “Output 2” is
selected and “Output 1” is muted. Connect the input signal to the IN jack, the send jack (S-6, S-7, or S-8) to one amplifier or
other device, and the OUT jack to the second amplifier or other device. Leave the return jack (R-6, R-7, or R-8) unconnected.

3)Input Selector

In this configuration the loop functions as an input or source selector, selecting one of two input signals to be fed to a single
output. When the loop is on the “Input 1” signal (IN jack) is switched to the OUT jack. When the loop is off the “Input 2” signal
(RETURN jack) is switched to the OUT jack. Leave the send jack (S-6, S-7, or S-8) unconnected.

4)Output (Send) ON/OFF Switch

A separate loop is also an ideal way to simply turn a signal on or off. When the loop is on the input signal is output via the send
jack (S-6, S-7, or S-8), and when the loop is off the send jack output is muted. This is a handy way to turn a D.I. send on or off.

9

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

 

Содержание PEC-2

Страница 1: ...Rev 1 4 PPD0830 03...

Страница 2: ...this owner s manual thoroughly and keep it in a safe place for future reference CONTENTS 1 PEC 2 Main Features 3 2 Precautions 3 3 Quick Start Guide 4 4 Front Panel Nomenclature Operation 5 5 Rear Pan...

Страница 3: ...nnectors provided for easy integration with MIDI control systems Link Mode allows two PEC 2 units to be linked for control of up to 16 loops the loops of each PEC 2 unit can be switched individually R...

Страница 4: ...rams 12 x 7 In the PEC 2 PGM mode banks are selected via the BANK and BANK switches and individual programs are selected via the PGM1 PGM7 switches The currently selected bank and program are shown on...

Страница 5: ...nts the selected parameter in the EDIT mode MUTE Switch When this switch is engaged and the MUTE LED is flashing a mute circuit located between LOOP 5 and the OUT 1 and OUT 2 jacks is activated so tha...

Страница 6: ...feed the signal from either the buffered or non buffered input to the tuner IN LOOP6 LOOP8 Inputs for the PEC 2 s three separate loops S 6 S 8 Sends 6 8 Normally Closed These are the send jacks for s...

Страница 7: ...PEC 1 were re examined and re designed to reduce switching noise to an absolute minimum Separate Loops 1 Loops 6 through 8 are totally independent and use the same precision mechanical relays as loop...

Страница 8: ...IRECT mode the loops on either unit can be directly turned on or off as required 2 REMOTE Mode With this function you could place one PEC 2 unit on stage and another in the wings and use one or the ot...

Страница 9: ...minated When the loop is off Output 2 is selected and Output 1 is muted Connect the input signal to the IN jack the send jack S 6 S 7 or S 8 to one amplifier or other device and the OUT jack to the se...

Страница 10: ...ch You can then use the INC and DEC switches to turn the memory protect function on or off respectively Once the required selection has been made press the ENTER switch to confirm the selection and re...

Страница 11: ...when the corresponding switch is pressed In the edit mode use the DEC and or INC switches to select edit menu number 6 6cc and press the ENTER switch You can then use the INC and DEC switches to selec...

Страница 12: ...after completing step 3 above press the INC 1 switch one more time so that tdt transmit data appears on the display then press ENTER YES will flash on the dis play Press ENTER again and data transmis...

Страница 13: ...13 10 System Examples...

Страница 14: ...14...

Страница 15: ...rbox Provolt9 PV 9 DC9V Output Connectors x 6 Double Filtering on each of the Provolt9 outputs ensures exceptionally clean power supply The Provolt9 Auto Voltage Controller ensures that approximately...

Страница 16: ...3 21 7 Tsurumi Chuo Tsurumi ku Yokohama shi Kanagawa 203 0051 JAPAN TEL 81 45 510 4060 FAX 81 45 510 4061 E MAIL overseas1 pacifix ltd com www providence ltd com...

Отзывы: