![Protool VCP 700 E-L Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/protool/vcp-700-e-l/vcp-700-e-l_instruction-manual_1620465023.webp)
23
Troubleshooting
Fault
Motor does not start
Motor does not run in automatic
mode
The acoustic warning sounds
(Reduced suction power)
(VCP 700 E-M only)
No suction power during wet
cleaning
The vacuum cleaner switches off
during wet cleaning
Voltage fluctuations
Cause
Fuse of the mains socket has
blown
Overload protection switch has
tripped
Self-acting carbon brush is worn
Power tool is defective or not
connected properly
The power rating of the electrical
tool is too low
Suction power selected with
suction power control is too low
Hose diameter is not right for
switch position
Clogged suction hose/nozzle
Filter bag is full
Filter element is clogged
Defective cleaning mechanism
Tank is full (Float does not close
the suction opening)
Tank is full
Impedance of power supply is
too high
Remedy
Connect mains fuse
Switch off the vacuum cleaner
and allow it to cool for approx.
5 minutes. If the cleaner cannot
be started again, contact the
PROTOOL service department
Have carbon brushes changed by
PROTOOL Service
Check that the power tool works
or that the plug is inserted
correctly
Note that minimum power rating
is P > 40 W
Set suction power in accordance
with section “Suction power
control”
Set correct switch position for
hose diameter
Clean suction hose/nozzle
See section “Replacing the filter
bag”
See section “Cleaning the filter
element” and “Replacing filter
element”
Contact PROTOOL Service
Switch off the cleaner. Empty the
tank
Switch off the cleaner. Empty the
tank
Connect the cleaner to another
socket closer to the fuse box.
Voltage fluctuations over 7%
should not occur if the impedance
at the transfer point is
≤
0.15
Ù
Содержание VCP 700 E-L
Страница 1: ...VCP 700 E L VCP 700 E M...
Страница 6: ...6 10 14 9 8 12 3 4 5 12 5 6 13 1 2...
Страница 116: ...116 PROTOOL 30 30 16 A 25 A 20 1 5 2 2 5 2 20 50 2 5 2 4 0 2 1 2...
Страница 117: ...117 PROTOOL PROTOOL VCP 700 E L 1 3 L VCP 700 E M 0 1 3 1 2 3 4 1 1 2...
Страница 119: ...119 1 3 VCP 700 E L 632 737 632 735 1 2 0 1 3 0 1 3 VCP 700 E M 632 737 632 735 1 2 3...
Страница 120: ...120 1 2 3 4 5 6 2 1 2 1 2 3 4 5 2 1 2 3 4 5 2 1 1 2 2 3 3 3...
Страница 121: ...121 4 5 6 4 7 5 PROTOOL 8 6 9 7 10 11 12 13 1 2 3 4 3 4 4 5 5 6 4 a a a e e 2002 96 1 3 1 2...
Страница 122: ...122 VCP 700 E M 5 PROTOOL PROTOOL 40 PROTOOL 0 15 7...
Страница 143: ...143 PROTOOL 30 mA 30 ms 16 A 25 A 20 m 1 5 mm2 2 5 mm2 20 50 m 2 5 mm2 4 0 mm2 IEC 1 2...
Страница 144: ...144 PROTOOL PROTOOL VCP 700 E L 1 mg m3 L VCP 700 E M 0 1 mg m3 1 2 3 MAK 4 1 1...
Страница 146: ...146 2 3 MAN 10 MAK 1 mg m3 VCP 700 E L 632 737 632 735 1 2 MAK 0 1 mg m3 MAK 0 1 mg m3 VCP 700 E M 632 737 632 735 1 2 3...
Страница 147: ...147 1 2 3 4 5 6 2 1 2 1 2 3 4 6 2 1 2 3 4 5 2 1 3...
Страница 148: ...148 1 2 2 3 3 4 5 6 4 7 5 PROTOOL 8 6 9 7 10 11 12 13 1 2 3 4 3 4 4 5 5 6 4 1 3 1 2...
Страница 149: ...149 5 PROTOOL PROTOOL 40 W PROTOOL 7 0 15 A VCP 700 E M...
Страница 160: ......