background image

Direction of applying the load

Fig.3. Directions load device.

Fig.4. 

Example: mounting to concrete surface

Example steel surface mounting

Screw M12x50

Used to connect the M12 screws of any length but strength class 8.8. not less than:
Stainless steel screws A2 - 70
Galvanized steel bolts - 8.8

Fig.8. Example steel surface mounting

3

Structural 
Anchor Point
min. 12 kN

position
of fall arrest
device

level
of attachment
point of
a harness

Structural 
Anchor Point
min. 12 kN

position
of fall arrest
device

level
of attachment
point of
a harness

OK !

F

O

B

ID

D

E

N

!

R

Example: mounting to concrete surface

Proper use of the product.

H

The clearance distance H between the work level and the ground level ( or other obstacle) has to be determined for the 

whole protection system depending on used equipment ( fall arrester or lanyard). the clearance distance is the sum of 
distances for each device. 

Содержание AT 183

Страница 1: ...FILLED IN ONLY BY A COMPETENT PERSON MODEL AND TYPE OF EQUIPMENT REF NUMBER DEFECTS NOTED REPAIRS CARRIED OUT AND OTHER REVELANT INFORMATIONS NAME AND SIGNATURE OF COMPETENT PERSON PERIODIC EXAMINATION NEXT DUE DATE PROTEKT 93 403 LODZ ul Starorudzka 9 POLAND TEL 48 42 680 20 83 FAX 48 42 680 20 93 www protekt com pl Notified body which supervises the production of the equipment APAVE SUDEUROPE SA...

Страница 2: ...only be used by a person trained and competent in its safe use personal protective equipment must not be used by a person with medical condition that could affect the safety of the equipment user in normal and emergency use a rescue plan shall be in place to deal with any emergencies that could arise during the work it is forbidden to make any alterations or additions to the equipment without the ...

Страница 3: ...nchor Point min 12 kN position of fall arrest device level of attachment point of a harness Structural Anchor Point min 12 kN position of fall arrest device level of attachment point of a harness OK F O B I D D E N R Example mounting to concrete surface Proper use of the product H The clearance distance H between the work level and the ground level or other obstacle has to be determined for the wh...

Страница 4: ... max 114 3 mm Anchor size M12 Standard anchorage depth tfix 97 3 mm Reduced anchorage depth tfix 82 3 mm Key size SW 19 mm 12 mm Torque moment Tinst 50 Nm Standard anchorage depth Depth of drill hole h1 90 mm Embedment depth hnom 82 mm Effective anchorage depth hef 65 mm Reduced anchorage depth Depth of drill hole h1red 75 mm Embedment depth hnomred 67 mm Effective anchorage hefred 50 mm Nominal d...

Отзывы: