7.3 ROOF 

PANELS

SEAM STYLES

: Vertical standing seams only 

COMPATIBLE ROOF PANELS

: See Table 1 for a list of compatible roof panels.

Table 1 - Compatible Roof Panels

A&S Double-Lok, 22 ga steel

Firestone UC3, 24 ga steel

A&S Double-Lok, 24 ga steel

Firestone UC4, 24 ga steel

A&S Ultra Dek, 22 ga steel

Firestone UC6, 24 ga steel

A&S Ultra Dek, 24 ga steel

MBCI Lok Seam, 22 ga steel

AB Martin Roofing AB Seam 19.5, 24 ga steel

MBCI Lok Seam, 24 ga steel

AEP Span Design Span hp, 22 ga steel

MBCI UltraDek, 22 ga steel

AEP Span High Seam, 24 ga steel

MBCI UltraDek, 24 ga steel

AEP Span Snap Seam, 22 ga steel

McElroy Metals Master-Lok 90 ML90, 22 ga steel

AEP Span Snap Seam, 24 ga steel

McElroy Metals Master-Lok 90, ML90 24 ga steel

American Buildings Company Standing Seam II Panel, 24 ga 

steel

McElroy Metals Medallion-Lok, 22 ga steel

Architectural Building Components Perma seam, 22 ga steel

McElroy Metals Medallion-Lok, 24 ga steel

Architectural Building Components Perma seam, 24 ga steel

Merchant & Evans #305, 24 ga steel

Bax Steel Buildings Bax-Lock, 22 ga steel

Mesco Ultra Dek, 22 ga steel

Bax Steel Buildings Bax-Lock, 24 ga steel

Mesco Ultra Dek, 24 ga steel

BC Steel Buildings BCL 24-SD, 22 ga steel

Metal Sales Vertical Seam, 22 ga steel

BC Steel Buildings BCL 24-SD, 24 ga steel

Metal Sales Vertical Seam, 24 ga steel

Berridge Cee-Lock, 24 ga steel

NCI/Midwest Metallic Ultra Dek, 22 ga steel

Butler MR24, 24 ga steel

NCI/Midwest Metallic Ultra Dek, 24 ga steel

Ceco CXP, 22 ga steel

New Tech Machinery S5 5500 Snap Lock 1 1/2, 24 ga steel 

Ceco CXP, 24 ga steel

New Tech Machinery SS675 Sanp Lock 1 3/4, 24 ga steel

Central States Manufacturing Central Loc, 22 ga steel

Petersen Aluminum Corp Snap Clad, 22 ga steel

Central States Manufacturing Central Loc, 22 ga steel

Petersen Aluminum Corp Snap Clad, 24 ga steel

Central Texas Metal Roofing Supply ShurLoc 175, 22 ga steel

Star Building Systems Starshield, 22 ga steel

Central Texas Metal Roofing Supply ShurLoc 175, 24 ga steel

Star Building Systems Starshield, 24 ga steel

Centria SDP175, 22 ga steel

Taylor Metal Easy Lock Standing Seam, 24 ga steel

Centria SDP175, 24 ga steel

U.S. Metals US-175LS, 22 ga steel

Copper Sales UC3, 24 ga steel

U.S. Metals US-175LS, 24 ga steel

Copper Sales UC4, 24 ga steel

Una-Clad UC3, 24 ga steel

Copper Sales UC6, 24 ga steel

Una-Clad UC4, 24 ga steel

Custom Bilt Metals SL-175,0 24 ga steel

Una-Clad UC6, 24 ga steel

Dimensional Metals DL-15, 24 ga steel

United Structures of America Guardian I, 22 ga steel

Dimensional Metals IL-20, 22 ga steel

United Structures of America Guardian I, 24 ga steel

Dimensional Metal IL-20, 24 ga steel

United Structures of America Guardian II, 22 ga steel

Englert Series 2000, 22 ga steel

United Structures of America Guardian II, 24 ga steel

Englert Series 2000, 24 ga steel

Varco Pruden SSR, 24 ga steel

Fabral 3” Snap Rib, 24 ga steel

Whirlwind Building Systems Super Seam II, 22 ga steel

Fabral Slim Seam, 24 ga steel

Whirlwind Building Systems Super Seam II, 24 ga steel

Fabral Thin Seam, 24 ga steel

Содержание Standing Seam Roof Anchor

Страница 1: ...ine 1 2 LIMITATIONS Consider the following application limitations before using this equipment IMPORTANT This anchor shall be installed and used under the supervision of a Qualified Person1 as part of a complete personal fall arrest system that maintains a safety factor of at least two 1 A ROOF PANELS The Standing Seam Roof Anchor must only be used on structural standing seam roof panels that meet...

Страница 2: ...plication and use See section 4 0 1 3 APPLICABLE STANDARDS Refer to applicable standards including local state and federal requirements for more information on personal fall arrest systems and associated components 2 0 SYSTEM REQUIREMENTS 2 1 COMPATIBILITY OF COMPONENTS Protecta equipment is designed for use with Capital Safety approved components and subsystems only Substitutions or replacements ...

Страница 3: ... manner that does not allow the connector to align properly while under load 2 4 PERSONAL FALL ARREST SYSTEM Personal fall arrest systems used with this equipment must meet applicable state federal and OSHA requirements A full body harness and Self Retracting Lifeline must be used with the Standing Seam Roof Anchor The personal fall arrest system must limit fall arrest forces to 1 800 lbs 8 kN The...

Страница 4: ...ffect a worker s ability to withstand falls Pregnant women and minors must not use this equipment 3 1 BEFORE EACH USE OF THIS EQUIPMENT INSPECT ACCORDING TO SECTION 5 0 OF THIS MANUAL 3 2 PLAN YOUR SYSTEM BEFORE INSTALLATION CONSIDER ALL FACTORS THAT WILL AFFECT YOUR SAFETY DURING USE OF THIS EQUIPMENT CONSIDER THE FOLLOWING WHEN PLANNING YOUR SYSTEM A ANCHORAGE Select an anchorage that meets the ...

Страница 5: ...The SRL must be secured in the swivel bracket with the included 5 8 inch bolt Figure 8 The bolt should pass through the holes in the swivel bracket and the anchor point e g swivel eye on the SRL Do not substitute hardware other than provided with the standing seam anchor If the bolt will not fit through the designated anchor point on the SRL or if the SRL does not fit within the swivel bracket the...

Страница 6: ... of the consequences of improper installation or use of this equipment This user manual is not a substitute for a comprehensive training program Training must be provided on a periodic basis to ensure proficiency of the users WARNING Training must be conducted without exposing the trainee to a fall hazard Training should be repeated on a periodic basis 5 0 INSPECTION 5 1 FREQUENCY BEFORE EACH USE ...

Страница 7: ... clamp plate and seam clamp fasteners to the torque requirements stated in Figure 8 Step 5 Inspect the self retracting lifeline and the full body harness according to the manufacturer s user instruction manuals 5 3 If the inspection reveals an unsafe or defective condition remove the Standing Seam Roof Anchor from service and destroy or return it to an authorized service center for repair IMPORTAN...

Страница 8: ... 24 ga steel NCI Midwest Metallic Ultra Dek 24 ga steel Ceco CXP 22 ga steel New Tech Machinery S5 5500 Snap Lock 1 1 2 24 ga steel Ceco CXP 24 ga steel New Tech Machinery SS675 Sanp Lock 1 3 4 24 ga steel Central States Manufacturing Central Loc 22 ga steel Petersen Aluminum Corp Snap Clad 22 ga steel Central States Manufacturing Central Loc 22 ga steel Petersen Aluminum Corp Snap Clad 24 ga stee...

Страница 9: ...9 8 0 LABELING 8 1 THESE LABELS MUST BE PRESENT AND FULLY LEGIBLE Warning Label ID Label ...

Страница 10: ...SE INSPECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By ...

Страница 11: ...SE INSPECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By ...

Страница 12: ... dba CAPITAL SAFETY USA CAPITAL SAFETY warrants to the original end user End User that its products are free from defects in materials and workmanship under normal use and service This warranty extends for the lifetime of the product from the date the product is purchased by the End User in new and unused condition from a CAPITAL SAFETY authorized distributor CAPITAL SAFETY S entire liability to E...

Отзывы: