background image

WARNING : 

Before proceeding with the control board commissioning, check which kind of limit 

switch is installed on the motor.

The control board is preset to work with electromechanical limit switches

In case of magnetic limit switch please select parameter: 

Method 

1

 = 

STANDARD

Method 

2

 = 

SEQUENTIAL

Warning: 

Before powering up and programming the control unit refer to the wiring scheme and then:

1

 

Check that the motor connections are correct

2

 

Check that the photocell connections are correct

 

Important:

 

 

If the photocells are not installed in closing phase, you must link terminals 3 and 9.

 

 If the photocells are not installed in opening phase, you must link terminals 4 and 9.

3

 

Check that the control connections are correct.

 

Important:

 

If an emergency stop button is not fitted, you must link terminals 2 and 8.

4

 

Use  the  motor  release  key  supplied  to  disengage  the  electric  motor  from  the 
mechanical drive; then close the gate and re-engage.

5

 

Power the control unit up

STANDARD PROGRAMMING PROCESS

 (

Method 1)

a

)  Give a 

START 

signal (terminal 1 and terminal 8). 

 

After an opening movement of about 240mm, the deceleration phase will start (since 

the control board is pre-adjusted for an opening of 2,50 m). T

 

he motor will wait about 3 seconds and after that will start again with the closing phase.

b

)  Give a 

START

 signal to verify which functions and times are not suitable with the 

installation and take note.

c

)  Enter the programming phase through the 

buttons A

 and 

to reach the wished 

parameter

d

)  Use the buttons 

C

 

and 

D

 to change or confirm every single parameter

e

IMPORTANT:

 save the changes by selecting the parameter        and pushing the

 

button C

.

Example:

 

Increase the motor working time by 5 seconds

    

  

 

With the switched on control board , ensure that the display shows :

 

 

Press 

button

 

A

until the display shows

 

                    

Press 

button

 

B

until the display shows

 

                                       

Wait

until the display shows

 

 

Press 5 times the 

C

until the display shows

 

                      

Press 

button B

ntil the display shows

u

 

 

Press the button C for some seconds

ntil the display shows

u

The motor working time has been increased from 21 to 26 seconds

SEQUENTIAL PROGRAMMING 

(

method 2)

SLIDING GATE SEQUENTIAL PROGRAMMING

a

)  Press 

button A 

(steps through the top menu) until the display shows 

b

)  Press 

button B 

(steps through the sub-menu) until the display shows 

c

)  Give a 

START 

signal: the leaf starts opening and the display shows 

d

)  Wait until the leaf has done the 90% of the opening cycle and then give 

another 

START 

signal: the display shows        and the deceleration phase 

begins.

e

)  When the opening phase has been completed (

OPENING LIMIT 

SWITCH

) and the display shows       , the control board has stored the 

opening and deceleration times and starts calculating the “

stay open

” 

(pause) time

f

At the reaching of the desired pause time, give another 

START

 impulse. 

 

The control board has stored the “

stay open

” time and the gate starts the 

closing cycle.

g

)  When the closing cycle has completely finished, till the complete closure 

of the gate, the control unit automatically exits from the sequential 
programming process and all the working times have been saved.

PROGRAMMING THE Q60S W PARAMETERS

SELF-DIAGNOSIS DISPLAY MESSAGES

U

S

 I

 I

 I

P

AS

P E

C

F

Closing phase photocell
beam interruoted 
or wiring fault

Pedestrian start signal
(short circuit between 
terminal7 & 8)

Limit switch 
in opening phase

Motor problem (wiring
fault, obstruction or
torque setting too low)

Limit switch 
in closing phase

F A

5

C

A

.

P A

I

I

S U

2 5

— —

— —

Photocell’s test error

E

Both opening and closing
phase photocell beam
interrupted or wiring fault

Start signal
(short circuit between 
terminal 1 & 8)

Stop pressed
(or open circuit between 
terminal 2 & 8)

Radio fob
continuously
trasmitting

SPECIAL FUNCTIONS

P A

E

P

2

P

 

AUTOMATIC CLOSING  FUNCTION

When set to YES

 (“SI”):

-  an impulse during the opening phase will stop the 

motors until another impulse is received

-  an impulse during the closing phase will stop and 

reverse the motors

When set to NO

, the step-by-step operation is active:

st

-  1  impulse starts the 

opening phase

nd

-  2  impulse stops the 

opening phase

rd

-  3  impulse starts the 

closing phase

 MULTI-USER FUNCTION  

when set to 

YES

 (“SI”):

The  control  unit  will  not  accept  any 
command during the opening phase 

            PROGRAMMING THE RADIO

LLLLL

IMPORTANT

BEFORE PROGRAMMING FOR THE FIRST 

TIME THE RADIO RECEIVER, DELETE ALL THE RECORDED TEST CODES. 

SEE FUNCTION          AT THE BOTTOM OF THIS CHAPTER

IN CASE OF TRANSMITTERS WITH DIP-SWITCHES, SET THE 

MICROSWITCHES TO CREATE A NEW PERSONAL CODE. 

(For security reasons avoid to set the microswitches all in OFF or all in ON position).

IN CASE OF HIT TYPE TRANSMITTERS, THE ABOVE MENTIONED 

PROCEDURE IS NOT NECESSARY BECAUSE EACH TRANSMITTER 

COMES WITH ITS OWN CODE RANDOM.

DISPLAYING STORED CODES

 

 

Press the 

button A 

repeatedly until the display shows 

 

 

Press 

button B

 until the display shows 

 

 

The display will now cycle trough each stored code from 01 to 50.

 

 

TO ERASE A SINGLE STORES CODE

 

 

Press 

button D

 when the number of the code to be removed is displayed

STORING NEW REMOTE CONTROL CODE

Press the 

button A

 repeatedly until the display shows 

  Press 

button B

 until the display shows

Press and hold the remote control button until a dot appears on the display (this 
means  that  the  receiver  is  ready  to  store  a  new  code)  and  simultaneously 
press 

button C

 to store the new code

STORING NEW REMOTE CONTROL CODE  with STOP function

Press the 

button A

 repeatedly until the display shows 

Press 

button B 

until the display shows 

Press and hold the remote control button until the dot appears on the display 
and simultaneously press 

button C

 to store the new code.

 

STORING NEW REMOTE CONTROL CODE  with PEDESTRIAN function

Press the 

button A

 repeatedly until the display shows 

Press 

button B

 until the display shows 

Press and hold the remote control button until the dot appears on the display 
and simultaneously press

 button C

 to store the new code

DELETING ALL STORED CODES

Press the 

button A

 repeatedly until the display shows 

Press 

button B

 until the display shows 

Press and hold 

button D

 until the display shows 

 

 

This indicates that all the codes have been erased

A

A

A

A

A

P

C

P

C

P

P

P

P

C

C

C

A

NO

F

YES

F

PHOTOCELL OR SAFETY RUBBER EDGE