Specifications:
Dimension
:
Package 710*660*1190mm; Unpacked machine 610*595*1075mm
3
Input power
:
AC220V±10
%
~50/60Hz
,
or AC110V±10
%
~60Hz
Compressor power
:
3/8HP
Average gas state refrigerant recovery speed (through charge/suction port)
:
0.25Kg/min.
Hand valves free.
Recovery rate: 96%.
Vacuum pump capacity
:
60L/min, non-sparkle.
Accuracy of gas cylinder load cell
:
±10g
New oil bottle capacity
:
250ml
Used oil bottle capacity: 400ml
Max. Pressure
:
20bar
Charge speed
:
2Kg/Min(max.)
LCD display
:
4.3-inch,TFT full color
High pressure gauge range
:
-1bar~40bar
Low pressure gauge range
:
-1bar~22bar
A/C database included, update through USB port.
Automatic service reminding. The equipment provides 600 operations totally (each recovery or vacuum
counts for one operation, and automatic mode counts for 2 operations) between regular maintenance, When