Congratulation on the purchase of the AC-200

Refrigerant Processor

This is a very good investment you have made for your workshop. This system will help your technicians in achieving their
best capability in diagnosing and rectifying air-conditioning issues, thus increasing productivity and profitability for your
business. This system can be customized to suit each individual workshop needs. Our company would like to work with you
as partners in your business to help you achieve maximum return on your investment, so please do not hesitate to contact us
or our distributors, if we can be of any further assistance in relation to this equipment use and maintenance, or any
air-conditioning related issues. We are always here to help you in achieving higher productivity.

AC-200 is an ideal option for workshops that have limited equipment investment budget. Even economic, the machine is
robustly built, with luxurious features such as color LCD display, amply database and patented oil separator/manifold. The
unique design has facilitated quick load cell unlock, easy and economic maintenance (DIY maintenance recommended), self
troubleshooting and convenient USB upgrade etc..

General safety

The storage cylinder in this unit contains liquid refrigerant. Overfilling of the cylinder can cause violent explosion. Do
not disable the overfill safety feature. Always keep the cylinder on the load cell platform whenever operating the
machine.

The operator must carefully read the instruction manual before any operation is performed. Incorrect operations could
cause serious consequences, such as, improper A/C service, damage to automotive A/C system or damage to
equipment.

Only use cylinders which are recommended by the manufacturer and supplied with this equipment.

Avoid inhalation of refrigerant or oil vapor/mist, read material safety instructions on refrigerant and oil package.

Switch off and disconnect power cable from main supply before removing any cover or servicing the equipment, to
avoid electric shock which can be very dangerous or fatal.

Never use compressed air for leak testing the unit or vehicle A/C system!

Wear safety goggles and gloves, to protect eyes and skin from contact with refrigerant. Coming in contact with liquid
refrigerant can cause frostbite and blindness. If accidental contact is made with liquid refrigerant, wash effected area
with plenty of fresh water and contact a doctor.

Avoid using extension power cable than 1.5mm

2

copper core.

Keep gasoline or other flammable substances away from the equipment.

Always operate unit in a well-ventilated area and away from artificial heat

Содержание AC-200

Страница 1: ...PROTEC AC 200 USER MANUAL AC 200 USER MANUAL...

Страница 2: ...he storage cylinder in this unit contains liquid refrigerant Overfilling of the cylinder can cause violent explosion Do not disable the overfill safety feature Always keep the cylinder on the load cel...

Страница 3: ...FUNCTION TABLE 3 PART DESCRIPTION 4 OPERATION PREPARATIONS 5 EQUIPMENT CONNECTION Recovery vacuum oil injection charge auto mode 6 RECOVERY 7 VACUUM 7 OIL INJECTION 7 CHARGE 8 AUTO MODE 9 SYSTEM SETT...

Страница 4: ...er load cell 10g New oil bottle capacity 250ml Used oil bottle capacity 400ml Max Pressure 20bar Charge speed 2Kg Min max LCD display 4 3 inch TFT full color High pressure gauge range 1bar 40bar Low p...

Страница 5: ...rigerant from equipment gas cylinder to automotive A C system Auto mode Performs the selected functions in a fully automatic sequence The machine will stop automatically once all the selected function...

Страница 6: ...erant gas cylinder load cell 4 Drier filter 5 Manifold assembly 6 Assembly of solenoid valve and check valve 7 Base 8 Condenser and cooling fan 9 Compressor 10 Back cover1 11 Front wheel 12 Rear wheel...

Страница 7: ...on the machine select corresponding refrigerant type run recovery to fill equipment with refrigerant After one refrigerant tank is filled fill other tank with its corresponding refrigerant It is recom...

Страница 8: ...ion For recovery vacuum oil injection charge Auto Mode Warning Except the situations clearly stated in the manual during recovery and all other equipment operations please maintain the vehicle engine...

Страница 9: ...sture oil and foreign particles are separated from the refrigerant before it is stored in the internal refrigerant cylinder Vacuum Select Vacuum icon and press ENTER to start the process The Vacuum pr...

Страница 10: ...ual oil injection is effected by pressing right arrow key on control panel Please be aware that there is no oil load cell equipped in the machine the oil injection volume is calculated by injection ti...

Страница 11: ...icians to do calibration of load cells The load cell calibration is very simple and fast with just one step 1kg weight calibration step Warning Misoperation in calibration could bring about serious co...

Страница 12: ...message Click OpenFile to select update to update e g file RCC9A_V2 01 for main program update or Database_V2 02 for database update Then click Connect the PC displays the following message Click Pro...

Страница 13: ...displayed in the left beneath part of each operation interface Upon 480 operations having been made the machine displays the following message and users can continue using the equipment meanwhile mak...

Страница 14: ...service manual 2 Change compressor 3 Fasten pressure sensor connection to PCA or change the pressure sensor No change in recovery volume 1 No refrigerant in A C 2 Support screw of gas cylinder load c...

Страница 15: ...s not well sealed Remove solenoid 8 from valve base clean the solenoid valve and valve base During vacuum there is suction in old oil bottle The contact between solenoid valve 2 and valve base is not...