TEKTINO

AC-200-dual USER MANUAL V2.30

10/14

Auto. mode

Empty used oil vessel before the process.

You can select “Auto.mode” to do full cycle of recovery, vacuum, oil injection and charge.

In auto. Mode, the machine makes recovery, vacuum, oil injection and refrigerant charge in

sequence automatically, with data preset by users.

System setting

Select “system setting” icon and input PW 111111 (left and right arrow to move cursor, up and

down arrow to increase/decrease number) to enter system setting menu. In system setting,

“Language”, “Calibration”, “Database”, “Unit set”, “Empty container weight set” and “Component

test” can be inquired or reconfigured.

Language: Can change operation system language.

Calibration: It is suggested to have only professional technicians to do calibration of load cells. The

load cell calibration is very simple and fast, with just one step, 1kg weight calibration step.

Warning: Misoperation in calibration could bring about serious consequences to equipment or

vehicle A/C system.

Database: Users can access database of refrigerant/oil volume of different car makes and models.

Unit set: To set metric or American imperial unit. The two numbers displayed in the bottom part of

the interface are values of two tank load cells, for load cell diagnosis purpose.

Empty container weight set: The total load cell reading equals the sum of empty container weight

and net refrigerant content value. Thus, increase/decrease empty container weight, can

correspondingly decrease/increase refrigerant value displayed in the main operation interface.

Component test: Users can activate/dis-activate different electronic component of the machine. This

is for quick and easy diagnosis for troubleshooting.

Содержание AC-200-dual

Страница 1: ...PROTEC AC 200 dual USER MANUAL AC 200 dual USER MANUAL...

Страница 2: ...still highly recommended to leave maintenance job to specialized technicians self troubleshooting and convenient USB upgrade etc General safety The storage cylinder in this unit contains liquid refrig...

Страница 3: ...TABLE 3 PART DESCRIPTION 4 OPERATION PREPARATIONS 5 EQUIPMENT CONNECTION Recovery vacuum oil injection charge Tank fill auto mode 7 RECOVERY 8 VACUUM 8 OIL INJECTION 9 CHARGE 9 TANK FILL 9 AUTO MODE 1...

Страница 4: ...of dual gas cylinders one for R 134a one for HFO 1234yf 10KG New oil bottle capacity 250ml Used oil bottle capacity 400ml Dual condensers and cooling fans one for R 134a one for HFO 1234yf Max Pressu...

Страница 5: ...A C system Tank fill Transfer liquid refrigerant from an external refrigerant storage cylinder to equipment cylinder Auto mode Performs the selected functions in a fully automatic sequence The machine...

Страница 6: ...ad LP gauge R134a HFO1234yf Coupler connect fittings LCD screen HP gauge Fuse Power switch Vacuum pump New oil vessel Used oil vessel R134a refrigerant tank HFO1234yf Refrigerant tank R134a tank gauge...

Страница 7: ...2 When you need transport the machine please screw those bolts on Fill equipment with refrigerant New equipment is empty you need to fill the equipment with refrigerant and refrigeration oil Through t...

Страница 8: ...select refrigerant type If the refrigerant type selected is different from the refrigerant handled at previous operation the machine automatically recovers refrigerant inside machine pipelines and ma...

Страница 9: ...ment Connection For recovery vacuum oil injection charge Auto Mode Warning Except the situations clearly stated in the manual during all equipment operations please maintain the vehicle engine and A C...

Страница 10: ...internal refrigerant cylinder The machine should be left connected on the vehicle for a minimum time of 3 minutes longer in cold climates for any pressure increase test If after 3 minutes or longer if...

Страница 11: ...s ENTER to start the process You can manually set charge amount with volume or select Charge by database to set charge amount by car make and model You can choose to charge through high side low side...

Страница 12: ...to do calibration of load cells The load cell calibration is very simple and fast with just one step 1kg weight calibration step Warning Misoperation in calibration could bring about serious conseque...

Страница 13: ...message Click OpenFile to select update to update e g file AC200 DUAL_V2 01 for main program update or Database_V2 02 for database update Then click Connect the PC displays the following message Clic...

Страница 14: ...re next maintenance is displayed in the left beneath part of each operation interface Upon 480 operations having been made the machine displays the following message and users can continue using the e...

Страница 15: ...to service manual 2 Change compressor 3 Fasten pressure sensor connection to PCA or change the pressure sensor No change in recovery volume 1 No refrigerant in A C 2 Support screw of gas cylinder loa...

Страница 16: ...ve base is not well sealed Remove solenoid 8 from valve base clean the solenoid valve and valve base During vacuum there is suction in old oil bottle The contact between solenoid valve 2 and valve bas...