PGA-710B Autoanalysis System
B. PGA-710B Autoanalysis System Applica on So ware Flash Drive
The Autoanalysis System Applica ons Flash Drive includes the necessary programs to communi-
cate with, and operate the Autoanalyzer, install analy cal programs, drivers and addi onal Mi-
croso so ware. Before opening or loading so ware, please be sure to review the Autoanalysis
System So ware license agreement.
C. Documenta on
Documenta on includes this Opera ng Manual, a Quick Start Guide, a Product Key Number for
access to the Applica on So ware, a Tes ng Guide for Flooring and Ionizers, and a Help
fi
le link in
the Applica on So ware.
D. Connec ons & Accessories
The following cables and accessories are provided:
1. USB cable for connec on of the PGA-710B Autoanalyzer to a computer USB port. Computer is
not provided. (Part Number: PGA-710USB)
2. Shielded analog cable connects the analog output of a Prostat PFM-711A Field Meter (
fi
eld
meter not provided) and the signal input of the PGA-710B Autoanalyzer (Part Number: PGA-
710AnaCab).
3. The shielded voltage measurement cable with ground is used for body voltage, body reten-
on and other measurement. Connect the green shield lead to ground to reduce the e
ff
ects of
ambient electrical noise. (Part Number: PGA-710ChgGen lead)
4. Input
Shor ng Shunt used to “zero” the PGA-710B Autoanalyzer during normal opera ons.
(Part Number: PGA-710CC)
5. Body voltage Hand Wand and Cable accessories. (Part Number: PFA-861-H)
6. Ba ery Charger (Part Number: PGA-710 Charger)
E. Shielded Measurement Cable
The shielded measurement cable is intented for use with the Prostat CPM-720 charge plate moni-
tor for measuring body voltage genera on, charge reten on, remote equipment and other elec-
trosta c voltage sources. The signal conductor insula on is Red and the shield insula on is Green.
Connect the Red lead to the CPM and the object being measured. Connect the Green shield to
ground to reduce the e
ff
ects of ambient electrical noise and transmi ed energy. Do not connect
the shield to the ground plate of the CPM.