![ProSoft MVI46-S3964R Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/prosoft/mvi46-s3964r/mvi46-s3964r_user-manual_1618866051.webp)
Reference MVI46-S3964R
♦
SLC Platform
Siemens 3964R Protocol
ProSoft Technology, Inc.
Page 51 of 74
Send Block for Module to send to CP (Block 1)
Offset Data
Length
0 9X1X
1
1 Header
10
11 Data
50
Send Block for Module to send to CP (Blocks 2 to 4)
Offset Data
Length
0
9X2X, 9X3X, 9X4X
1
1 Data
60
Request for data Block from Module to respond to CP
Offset Data
Length
0 910X
1
1 Reserved
2
3 1145h
1
4
Data Block (DB)
1
5
Data Word (DW)
1
6
Number of Data Words
1
7 Coordination
Bytes
1
8
Data Type (4Dh/44h)
1
9 to 12
Reserved
4
Receive Data from CP (First Block)
Offset Data
Length
0 910X
1
1 Reserved
1
2
Data Block 1
1
3 1141h/11FFh
1
4
Data Block (DB)
1
5
Data Word (DW)
1
6
Number of Data Words
1
7 Coordination
Bytes
1
8
Data Type (4Dh/44h)
1
9 to 12
Reserved
4
13 Data
49
Receive Data from CP (Blocks 2 to 4)
Offset Data
Length
0 910X
1
1 Reserved
1
2
Data Block (2 to 4)
1
3 Data
59
April 17, 2008