Module Configuration
MVI46-S3964R
♦
SLC Platform
Siemens 3964R Protocol
ProSoft Technology, Inc.
Page 27 of 74
2.5.11 Priority
0 or 1
This parameter specifies whether the data is high priority or low priority. 0 = High
priority, 1 = Low Priority.
2.5.12 Protocol
0 or 1
0=3964 RK512, 1=3964
2.5.13 ACK Delay
Number of milliseconds to wait for ACK. The default is 1000 ms.
2.5.14 Setup Attempts
Number of times to try to connect to CP (Default 6)
2.5.15 Transmit Attempts
Number of times to try to transmit to CP (Default 6)
2.6
Download the Project to the Module
In order for the module to use the settings you configured, you must download
(copy) the updated Project file from your PC to the module.
To Download the Project File
1
In the tree view in ProSoft Configuration Builder, click once to select the
MVI46-S3964R module.
2
Open the
Project menu,
and then choose
Module
/
Download
. The program
will scan your PC for a valid com port (this may take a few seconds). When
PCB has found a valid com port, the following dialog box will open.