5.4.2 DH485 API Specific Error Codes
Error #
Description
0x0800
Command only permitted in master mode
0x0801
Command already active on the port
0x0802
Response to request timed out
0x0803
Unable to allocate memory for the request
0x0804
Illegal command or format
0x0805
Host could not complete request (hardware fault)
0x0806
Out of memory, file or rung does not exist
0x0807
Field has an illegal value
0x0808
Not enough fields in request message
0x0809
Too many fields in request message
0x080A
Symbol not found
0x080B
Symbol 0 or greater than maximum characters permitted in message
0x080C
Does not exist, illegal size
0x080D
File wrong size, address past end of file
0x080E
Data or file too large (memory not available)
0x080F
Request too large to transmit message (size+address > max message)
0x0810
Access denied
0x0811
Command cannot be executed
0x0812
Illegal data type information
0x0813
Illegal parameter, invalid data in search or command block
0x0814
File open by another node
0x0815
Program owned by another node
0x0816
Unknown error returned from host
0x0817
No message active on the port
5.5
Maximum Element Counts For Read/Write Commands
File Type Code
File Type
Bytes/ Element
0 Status
2
1 Bit
2
2 Timer
6
3 Counter
6
4 Control
6
5 Integer
2
6 Float
4
10 CIF
1