Connection
Adjust the right or left foot to make the machine stable.
Connect tab single-phase A.C, 100-240 VAC 50-60 Hz.
Release the emergency button.
Lamps are walking 1 by 1, put in a skate and then machine is ready to sharp.
Connect the dust-cleaners hose to the machine for automatic start of dust-cleaner when
grinding. Connect dust-cleaners hose with the machines hose.
Placement
The machine must be placed on a flat, steady workbench with a height between 80-100
cm.
The working area must be well lit. Keep work area clear. Cluttered areas and benches
invite injuries.
Issuing
The noise level of the machine is less than 70 dB.
During use of the machine, dust will occur and this dust must be taken away.
Clean the machine between every grinding.
Engagement
For information regarding the grinding machine the responsible operator must inform other
users about safety and maintenance instruction.
For safety reasons, modifications of the machine or its design are not allowed.
Maintenance
The ProSharp AS 1001-Portable is manufactured for low maintenance demands.
In your own interest and for your own safety, control and cleaning must be done before,
during and after grinding.
Remove the plug before carrying out any adjustment, servicing or maintenance.
Important!
All operators must read and understand original instructions regarding operation and
maintenance contained in this manual, before using the machine.
People under 18 years of age may NOT use the machine!
Never move the skate-holder by hand. Only use the arrows to move the skate-holder.
Only non-flammable vacuum cleaners should be connected to the AS 1001.