INSTRUCTIONS TO THE HOMEOWNER 

WARNING

Fire or Explosion Hazard.

Can cause severe injury, death or property damage.

1. IF YOU SMELL GAS:

 

Turn off the gas supply at the appliance service valve.

 

Do not light any appliances in the house.

 

Do not touch electrical switches or use the phone. Leave the 

building and use a neighbor’s phone to call your gas supplier.

 

If you cannot reach your gas supplier, call the fire department.

2. The water heater control must be replaced in event of any physical 

damage, tampering, bent terminals, missing or broken parts, 

stripped threads or evidence of exposure to heat.

WARNING

Scalding Hazard.

Can cause burns, severe injury or death.

Never move temperature setpoint knob past the HOT setting without 

checking water temperature at the faucet and readjusting until 

comfortably warm to the touch. Consider the ages and health of all 

who will come into contact with heated water.

IMPORTANT 

Follow the operating instructions provided by the manufacturer of 

your water tank appliance. The information in this form describes 

a typical water heater control application, but the specific controls 

used and the procedures outlined by the manufacturer of your 

appliance can differ, requiring special instructions. 

STOP: READ THE WARNINGS ABOVE.

If the appliance does not turn on when the setpoint knob is set several 

degrees above the previous temperature, follow these instructions:

1. Set the temperature setpoint knob to OFF.
2. Turn off the main gas valve to the appliance.
3. Wait five minutes to clear out any unburned gas. If you then smell gas, 

STOP! Follow step 1 in the warning above. If you DO NOT smell gas, 

continue with the next step.

4. Turn on the gas supply to the appliance.
5. Restart the appliance by performing lighting procedure.
6. Set the setpoint knob to the desired setting.
7. If the appliance does not turn on, turn off the gas supply to the appliance 

and contact a qualified service technician for assistance.

TURNING OFF THE APPLIANCE

Complete Shutdown

1. Turn device knob to OFF. Turn off the gas supply to the appliance. Appliance 

will completely shut off.

2. Follow the procedure in the 

Instructions to the Homeowner

 section above to 

resume normal operation.

!

!

Содержание PSW12414

Страница 1: ...tact with the control Where chemicals are suspended in air as in some industrial or agricultural applications protect the control with a cover Dust or Grease Accumulation Heavy accumulations of dust o...

Страница 2: ...Fuel Gas Code ANSI Z223 1 NFPA No 54 whichever applies Tubing installation must comply with approved standards and practices 1 Use a new properly reamed pipe free from chips If tubing is used make su...

Страница 3: ...ocedure 1 Start by turning the device knob to PILOT push the knob down and hold in position The pilot valve opens and allows gas to flow into the pilot burner NOTE If the gas pipe is full of air new i...

Страница 4: ...iance nameplate 3 IF CHECKING GAS INPUT WITH MANOMETER Make sure the manual gas shutoff switch is in the OFF position before removing outlet pressure tap plug to connect the manometer pressure gauge M...

Страница 5: ...flash count first Table 3 Troubleshooting with status light visual indication LED Error Code Number of LED Flashes Detected Failure Recommended Action Normal operation Knob in PILOT position 1 flash e...

Страница 6: ...pile for maximum output Thermopile output with time Fig 7 Thermopile output Follow diagram in Fig 6 Fig 6 Troubleshooting without status light Troubleshooting guide without status light TURN DEVICE KN...

Страница 7: ...g instructions provided by the manufacturer of your water tank appliance The information in this form describes a typical water heater control application but the specific controls used and the proced...