13
3.2.10 Live line test
1. Turn the rotary switch to the position Live.
2. Connect the test lead in red to Live input socket.
3. When a single test lead is inserted into jack L of power socket or
approaches a live conductor, if the meter detects AC voltage, the
meter's indicator for the intensity (high, medium and low) of induced
voltage signal will be on and the beeper sounds alarms for different
intensities.
3.2.11 Measuring temperature
Put the range switch at the gear of
℃
/
℉
. Insert the red plug of the
thermocouple into the end of
℃
, and insert the black plug of the
thermocouple into COM socket. Directly read the temperature value from
the display screen after the reading is stable.
Notes:
The maximum measuring temperature for the K-type thermocouple
dispatched at random is 250
℃
, and its instant measuring value can reach
300
℃
.
4. Technical parameters
4.1 Overall parameters
Operating environment:
600V CAT
Ⅳ
and 1000V CAT.
Ⅲ
Pollution level: 2
Altitude < 2000 m
Working temperature & humidity: 0~40
O
C (The requirements will not be
considered when temperature is less than 10
℃
and relative
humidity is below 80%).
Storage temperature & humidity: -10~60
O
C (batteries shall be removed
when RH is below 70%).
Coefficient of temperature: 0.1
accuracy/
O
C (<18
O
C or >28
O
C).
Allowable max voltage between terminal to be measured and ground:
1000V DC or 750V AC (valid value)
Protection of protective tube: mA position: protective tube FF 630mA/250V;
A position protective tube 10A/250V
Rotation rate: approximately 3 revolutions/second
Display unit: 6000 counts displayed on LCD screen. Automatically display
the symbol for unit in accordance with measurement function position.
Outrange indication: the LCD screen will display "OL".
Battery Low
indication: “
” will appear when the battery's voltage is
below the normal working voltage.