background image

Fault Elimination 

If the instrument does not work properly, please try the following 
tips to solve some general problems. If the problems still exist, 
please contact the maintenance center or the distributor. 

Fault Solution 

No Display 

Turn on power.   
Replace battery 

 symbol appearance 

Replace battery. 

Big display error 

Replace battery 

 

  This Instruction is subject to change without any further notice. 

  The content of this Instruction is considered correct, and in 

case readers find any errors and missing parts, please contact 
the manufacturer. 

  The Company shall not be held liable for any accidents and 

hazards resulted from the mal-operations by the user.   

  The function elaborated by this Instruction shall not be taken 

as the reasons for using the product for special purposes. 

 

 

17

Содержание mt-1232

Страница 1: ...MT 1232 3 3 4 Autorange Digital Multimeter User s Manual 2 st Edition 2012 2012 Copyright by Prokit s Industries Co Ltd ...

Страница 2: ...merits of clear reading stable performance and high reliability It could be used to measure DC voltage AC voltage DC current AC current resistance capacity frequency duty cycle diode and make on and off test Meanwhile it is available for unit symbol display automatic manual range switching automatic power off and alarm function The multimeter due to its complete functions performs with high measur...

Страница 3: ...C voltage above 25V current above 10mA AC power line with inductive load or power line during electric fluctuation is measured please beware of electric shock 2 Prior to measurement check if the measurement function switch is at the correct position Check if the test lead is contacted reliably connected correctly and grounded well etc in order to avoid electric shock 3 Only if the meter is used wi...

Страница 4: ... ground 7 Don t store and use it in the high temperature high humidity inflammable and strong magnetic field environment 8 It may damage to the meter and endanger the operator s safety if the voltage value beyond the permitted ultimate voltage value is measured The ultimate voltage value permitted for measurement is marked on the instrument panel and never measure the value exceeding the standard ...

Страница 5: ...attery immediately to ensure the measurement precision 13 It is not allowed to insert the test lead into the current terminal to measure voltage 14 Please don t change the circuits of the meter freely for fear that the meter will be damaged and the safety endangered 15 Description of Safety Symbols Warning DCV High Voltage Danger ACV DCA Ground ACA Double Insulation In accordance with the instruct...

Страница 6: ...f Capacitance function could be conducted by pressing this button 3 3 D Data hold Backlight Press the left side of this button the reading is locked press it again the left side the lock will release and back to normal measurement status Press the right side of this button over 3 seconds the backlight will come on press this button the right side again the backlight turns off 3 4 S Function Switch...

Страница 7: ...the auto power on mode working mode Properties General Feature 1 1 Display LCD 1 2 Max Display 3999 3 3 4 counts automatic polarity display and unit display 1 3 Measuring Method Dual integral A D converter 1 4 Sampling Range Approx 3 times sec 1 5 Over Range Indication Display OL 1 6 Low Battery Indication symbol appears 1 7 Operation Environment 0 40 C Relative Humidity 80 1 8 Storage Environment...

Страница 8: ...e testing point The voltage and polarity of the point where the red pen is contacted will be displayed on the screen Caution 1 Don t measure voltage over 600V Otherwise there is a danger of the meter being damaged 2 When measuring high voltage special attention should be given to personal safety and avoid your body getting in touch with high voltage circuit Range Accuracy Resolution 400mV 100uV 4V...

Страница 9: ...oint where the red test lead is contacted will be displayed on the screen Caution 1 Don t measure voltage over 600V Otherwise the meter will be damaged 2 When measuring high voltage special attention should be given to personal safety and avoid your body getting in touch with high voltage circuit Range Accuracy Resolution 4V 1mV 40V 10mV 400V 0 8 6d 100mV 600V 1 0 6d 1V Input Impedance 10MΩ Overlo...

Страница 10: ...e red pen is contacted will be displayed on the screen simultaneously Caution 1 If OL is displayed on LCD it indicates the tested current value has exceeded the present range limit please select higher range to complete the measurement 2 The Max input value is 400mA or 10A Depending on the terminal where the red test lead is contacted Range Accuracy Resolution 400uA 0 1uA 4000uA 1uA 40mA 10uA 400m...

Страница 11: ...sly Caution 1 If OL is displayed on LCD it indicates the tested current value has exceeded the present range limit please select higher range to complete the measurement 2 The Max input value is 400mA or 10A Depending on the terminal where the red test lead is contacted The overrated current will lead to fuse melt or even damage the meter Range Accuracy Resolution 400uA 0 1uA 4000uA 1uA 40mA 10uA ...

Страница 12: ...e the measurement When measuring the Resistor higher than 1MΩ the instrument will take several seconds to make the reading stable It is normal when measuring the high resistor 2 When the input terminal is open circuit it will display OL 3 When measuring in line resistor be sure that the power is off and all capacitors are discharged completely Range Accuracy Resolution 400Ω 0 8 5d 0 1Ω 4kΩ 1Ω 40kΩ...

Страница 13: ...est lead to the diode positive polarity OL symbol will be displayed on the screen 5 The complete diode testing includes forward and backward measurement if the result does not meet the above it means the diode is bad 6 Press S button to select the Continuity measurement mode 7 Connect the test leads to two points of the tested circuit If the built in buzzer sounds the resistance between the two po...

Страница 14: ...ement could be conducted by pressing REL button Caution 1 Fully discharge the tested capacitor in case it damages the meter 2 When measuring in line capacitor the power should be turned off and all capacitors should be discharged completely 3 It takes about 30 seconds to input stable reading at 100uF Range Range Accuracy Resolution 4nF 5 0 9d 1 pF 40nF 10pF 400nF 100pF 4μF 1nF 40μF 3 5 8d 10nF 100...

Страница 15: ... It is recommended to test weak signals by shielded cable under noisy circumstances 3 Select ACV when testing the frequency of high voltage Then press Hz DUTY button to enter frequency measurement status 4 Don t input voltage of over 250V DC or AC peak value in case it damages the meter Range Accuracy Resolution 1Hz 0 001Hz 10Hz 0 01Hz 100Hz 0 1Hz 1kHz 1Hz 10kHz 10Hz 100kHz 100Hz 1MHz 1kHz 10MHz 0...

Страница 16: ...you can read temperature from the screen and the data is in Centigrade Caution 1 When the input terminal is open circuit it will display the normal temperature 2 Don t change the temperature probe at random or the value accuracy could not be guaranteed 3 Don t measure voltage at temperature range Range Accuracy Resolution 20 1000 C 400 C 1 0 5d 400 C 1 5 15d 1 C Sensor K Type Thermocouple Nickel c...

Страница 17: ...battery shall be replaced The steps are as follows 5 1 Loosen the screw on the back cover that secures the battery case and remove the battery case 5 2 Remove the 1 5V batteries and replace them with two new ones Although a 1 5V battery of any standard can be used but in order to lengthen the operation life alkaline batteries should be used 5 3 Mount the battery case back and tighten the screw Pre...

Страница 18: ...ce battery Big display error Replace battery This Instruction is subject to change without any further notice The content of this Instruction is considered correct and in case readers find any errors and missing parts please contact the manufacturer The Company shall not be held liable for any accidents and hazards resulted from the mal operations by the user The function elaborated by this Instru...

Страница 19: ... 概述 MT 1232 是一款性能穩定 高可靠性 3 3 4 位元數字多用錶 儀 錶採用 15mm 字高 LCD 顯示器 讀數清晰 可用來測量直流電壓 交流電壓 直流電流 交流電流 電阻 溫度 電容 頻率 占空比 二極體及通斷測試 同時還設計有 單位符號顯示 自動 手動量程轉換 自動斷電及報警功能 該錶 功能齊全 測量準確度高 使用方便 是實驗室 工廠 無線電 愛好者及家庭的理想工具 二 開箱檢查 打開包裝箱取出儀錶 仔細檢查以下附件是否缺少或損壞 如有缺少或損壞請立即與經銷商聯繫 數字多用錶 一台 使用說明書 一本 錶棒 一付 溫度探頭 K 型熱電偶 一隻 防震套 裝於電錶上 一個 ...

Страница 20: ...格的錶棒 線 4 不要使用其他未經確認或未認可的保險管來更換儀錶內部的 保險管 只能換上同樣型號或相同規格的保險管 更換前 錶 棒必須離開被測量點 確保輸入端無任何信號 5 不要使用其他未經確認的電池來更換儀錶內的電池 只能換 上同型號或相同電氣規格的電池 更換前 錶棒必須離開被測 量點 確保輸入端無任何信號 6 在進行電氣測量時 身體切勿直接接觸大地 不要接觸可能存 在地電勢裸露的金屬端子 輸出口 引線夾等 通常使用乾 燥的衣服 膠鞋 膠墊以及其他絕緣材料 保持你的身體與大 地絕緣 7 不要在高溫 高濕 易燃 易爆和強磁場環境中存放及使用 8 測量超過儀錶所允許的極限電壓值有可能損壞儀錶和危及操 作人員的安全 在儀錶面板上標有儀錶所允許測量的極限電 壓值切勿測量超過此標準的安全 請勿輸入超過規定的極限 值 以防電擊和損壞儀錶 9 當錶棒線插入電流插座時切勿測量任何電壓以免損壞儀錶和 危及...

Страница 21: ...量程選擇開關 12 當 LCD 顯示 時 請及時更換電池以確保測量精度 13 不允許在電流檔去測量電壓 14 請不要隨意改變儀錶線路 以免損壞儀錶和危及安全 15 安全符號說明 警告 直流電壓 高壓 危險 交流電壓 直流電流 大地 交流電流 雙重絕緣 符合歐洲工 會指令 低電壓指示 保險絲 四 儀錶面板及按鍵功能說明 1 儀錶型號 2 液晶顯示器 顯示儀錶測量的數值 及單位 3 功能按鍵說明 3 1 Hz 頻率 占空比 在頻率檔 觸發此鍵 可選擇頻率或占空比 測量模式 交 直流電壓或交直 流電流檔位 觸發此鍵 可進行 電壓 頻率 占空比或電流 頻 率 占空比測量模式 20 ...

Страница 22: ... 4 旋鈕開關 用於改變測量功能及量程 5 輸入插孔 5 1 電流 電壓 二極體 電阻 電容 頻率 蜂鳴器 溫度的 輸入插孔 5 2 10A 輸入插孔 5 3 電壓 二極體 電阻 電容 頻率 蜂鳴器 溫度 及 小於 400mA 電流的輸入插孔 五 其他功能 自動關機 在測量過程中 功能按鍵和撥盤開關在 15 分鐘內均無動作時 儀錶會 自動關機 休眠狀態 以節約電能 在自動關 機狀態下 按動功能鍵或是轉動撥盤開關 儀錶會 自動開 機 工作模式 六 特性 1 一般特性 1 1 顯示方式 液晶顯示 1 2 最大顯示 3999 3 3 4 位元 自動極性和單位顯示 1 3 測量方式 雙積分式 A D 轉換 1 4 轉換速率 約每秒 3 次 1 5 過量程顯示 顯示 OL 1 6 低電壓顯示 符號出現 1 7 工作環境 0 40 相對濕度 80 21 ...

Страница 23: ...付 K 型熱電偶一支 2 技術特性 2 1 準確度 a 讀數 字數 保證準確度環境溫度 23 5 C 相 對濕度 75 校準保證期從出廠日起為一年 2 2 性能 功能 有 無 直流電壓 DCV 有 交流電壓 ACV 有 直流電流 DCA 有 交流電流 ACA 有 電阻 Ω 有 電容 CAP 有 頻率 Hz 有 二極體 通斷 有 溫度 C 有 2 3 1 直流電壓 DCV A 將功能開關轉至 檔 B 儀錶初始為自動量程狀態 顯示 AUTO 符號 C 將測試錶棒接觸測試點 紅錶棒所接的該點電壓與極性顯示在 螢幕上 注意 1 測量電壓切勿超過 600V 超過則有損壞儀錶電路的危險 2 當測量高電壓電路時 千萬注意避免人體觸及高壓電路 注意 人身安全 22 ...

Страница 24: ... 2 交流電壓 ACV 1 將黑錶棒插入 COM 插孔 紅錶棒插入 插孔 2 將功能開關轉至 檔 按動 SELECT 鍵選擇 AC 測量方 式 3 儀錶初始為自動量程狀態 顯示 AUTO 符號 4 將測試錶棒接觸測試點 紅錶棒接的該點電壓顯示在螢幕上 注意 1 測量電壓切勿超過 600V 如超過 有損壞儀錶電路的危險 2 當測量高電壓電路時 千萬注意避免人體觸及高壓電路 注意 人身安全 量程 準確度 分辨力 4V 1mV 40V 10mV 400V 0 8 6d 100mV 600V 1 0 6d 1V 輸入阻抗 大於 10MΩ 超載保護 600V 直流或 600V 交流峰值 頻率回應 50 200 Hz 顯 示 平均值響應 以正弦波有效值校準 23 ...

Страница 25: ...轉 至較高一檔 2 最大輸入電流為 400mA 或者 10A 視紅錶棒插入位置而定 超過額定的電流會將保險絲熔斷 甚至損壞儀錶 量程 準確度 分辨力 400uA 0 1uA 4000uA 1uA 40mA 10uA 400mA 1 0 10d 100uA 10A 1 2 10d 10mA 最大測量壓降 滿量程 mA 為 0 4V A 為 100mV 最大輸入電流 10A 不超過 15 秒 超載保護 0 4A 250V 自恢復保險絲 10A 250V 保險管 2 3 4 交流電流 ACA 1 將黑錶棒插入 COM 插孔 紅錶棒插入 插孔 最 大為 400mA 或插入 10A 插孔中 最大為 10A 2 將功能開關轉至電流檔 按動 SELECT 鍵選擇 AC 測量方 式 然後將儀錶的錶棒串入被測電路中 被測電流值及紅色 錶棒點的電流極性將同時顯示在螢幕上 24 ...

Страница 26: ...A 2 5 15d 10mA 最大測量壓降 滿量程 mA 為 0 4V A 為 100mV 最大輸入電流 10A 不超過 15 秒 超載保護 0 4A 250V 自恢復保險絲 10A 250V 保險管 頻率回應 10A 量程為 50 200 Hz 2 3 5 電阻 Ω 1 將黑錶棒插入 COM 插孔 紅錶棒插入 插孔 A 將量程開關轉至 Ω 檔 兩錶棒跨接在被測電阻上 B 如果測量阻值小的電阻 應先將錶棒短路 測得引線電阻 然後在實測中減去 注意 1 如 LCD 顯示 OL 表明已超過量程範圍 需將量程開關轉 至較高一檔 當測量電阻超過 1MΩ 以上時 讀數幾秒之後才 能穩定 這在測量高阻時是正常的 2 當輸入端開路時 則顯示 OL 3 測量線上電阻時 要確認被測電路所有電源已關閉及所有電 容都已完全放電 才可進行 25 ...

Страница 27: ...0Ω 量程時 應先將錶棒短路 測得引線電 阻 然後在實測中減去 2 3 6 二極體及通斷測試 A 將黑錶棒插入 COM 插孔 紅錶棒入 插孔 注 意紅錶棒極性為 極 B 將量程開關轉至 檔 按動 SELECT 鍵選擇二極 體測量方式 C 正向測量 將紅錶棒接到被測二極體的正極 黑錶棒接到被 測二極體的負極 顯示器即顯示二極體正向壓降的近似值 D 反向測量 將紅錶棒接到被測二極體的負極 黑錶棒接到被 測二極體的正極 顯示器顯示 OL 字樣 E 完整的二極體測試包括正反向測量 如果測試結果與上述不 符 說明二極體是壞的 F 按動 S 鍵選擇通斷測量方式 G 將錶棒連接到待測線路的兩點 如果內置蜂鳴器發聲 則兩 點之間電阻值低於約 50Ω 則內置蜂鳴器發聲 26 ...

Страница 28: ...禁止輸入電壓值 2 3 7 電容 F 1 將功能開關轉至 檔 2 將黑錶棒插入 COM 插孔 紅錶棒插入 插孔 3 用測試錶棒 注意紅錶棒極性為正極 將被測電容接入 COM 輸入端 螢幕將顯示電容容量 按動 REL 鍵可進行相對值測量 注意 1 對被測電容應完全放電 以防止損壞儀錶 2 測量線上電容時 需將線路電源關斷 並將電容充分放電 3 100uF 量程輸入讀數穩定時間約 30 秒 量程 準確度 分辨力 4nF 5 0 9d 1 pF 40nF 10pF 400nF 100pF 4μF 1nF 40μF 3 5 8d 10nF 100μF 5 0 8d 100nF 超載保護 250V 直流或交流峰值 27 ...

Страница 29: ...的頻率時 請選擇 ACV 檔 再按 Hz DUTY 按鍵 進入頻率測量狀態 4 禁止輸入超過 250V 直流或交流峰值的電壓 以免損壞儀錶 程量 準確度 分辨力 1Hz 0 001Hz 10Hz 0 01Hz 100Hz 0 1Hz 1kHz 1Hz 10kHz 10Hz 100kHz 100Hz 1MHz 1kHz 10MHz 0 5 10d 10kHz 0 1 99 9 僅供參考 0 1V 輸入靈敏度 0 7V 有效值 超載保護 250V 直流或交流峰值 2 3 9 溫度 C 1 將功能開關轉至 檔 2 將熱電偶感測器的冷端 自由端 負極 黑色插頭 插入 COM 插孔 正極插入 插孔中 熱電偶的工作 端 測溫端 置於待測物上面或內部 可直接從螢幕上讀取 溫度值 讀數為攝氏度 28 ...

Страница 30: ... 型熱電偶 鎳鉻 鎳硅 香蕉插頭 警 告 為了安全在此量程禁止輸入電壓值 七 儀錶保養 該儀錶是一台精密儀器 使用者不要隨意更改電路 1 請注意防水 防塵 防摔 2 不宜在高溫高濕 易燃易爆和強磁場的環境下存放 使用儀 錶 3 請使用濕布和溫和的清潔劑清潔儀錶外表 不要使用研磨劑 及酒精等烈性溶劑 4 如果長時間不使用 應取出電池 防止電池漏液腐蝕儀錶 5 注意 1 5V 電池使用情況 當螢幕顯示出 符號時 應 更換電池 步驟如下 5 1 卸下固定電池盒的螺絲 取出電池盒 5 2 取出 1 5V 電池 換上兩個新的電池 雖然任何標準 1 5V 電池都可使用 但為加長使用時間 最好使用鹼性電池 5 3 裝回電池盒 鎖緊螺絲 29 ...

Страница 31: ...或後蓋沒有上緊時 請不要使用此錶 4 在更換電池或保險絲前 請將測試錶棒測試點移開 並關機 八 故障排除 如果您的儀錶不能正常工作 下面的方法可以幫助您快速解決一 般問題 如果故障仍排除不了 請與維修中心或經銷商聯繫 故障現象 檢 查 部 位 及 方 法 沒顯示 電源未接通 換電池 符號出現 換電池 顯示誤差大 換電池 本說明書如有改變 恕不另行通知 本說明書的內容被認為是正確的 若用戶發現有錯誤 遺漏 等 請與生產廠家聯繫 本公司不承擔由於用戶錯誤操作所引起的事故和危害 本說明書所講述的功能 不作為將產品用做特殊用途的理 由 30 ...

Страница 32: ... 2012 Prokit s Industries Co LTD All rights reserved 2012001 T 31 ...

Отзывы: