Pump Application Conditions
Conditions
Description
Liquid Temperature
5°C to 40°C (41°F to 104°F)
ph liquid
5-8
Rated Output Variation
±10%
Voltage Variation without overheating
±10%, provided that it does not run
Frequency Variation
±1%
Maximum Allowable Pressure
0.2 MPa (2kgf/cm2) – Discharge pressure
Pump Installation
WARNING
•
Before installing the pump, check if the cable and cable entry have not been damaged during
transportation.
•
Be aware of the pump's center of gravity and weight. If the pump is not suspended properly, it
may lead to injury.
•
Never use the pump cable to suspend the pump. Doing so will damage the cab and may cause
electric shock or fire.
•
DO NOT dismantle the product before/during installation without any authorized instructions from
PRORIL
NOTICE
The following installation requirement must be implemented:
•
Use the pump dimensional drawing to ensure proper installation. If you have any questions, please
contact our representative or company.
•
Provide a suitable protective barrier around the pump working area.
•
Check for any explosion risk before pipe welding or use of any electrical hand tools.
•
Remove any remaining debris from the inlet piping system before installing the pump.
CAUTION
During piping work be aware if welding sparks, paint, concrete, etc. come in contact with the pump, it may cause
the pump to malfunction, and current leakage or electric shock may occur.
Pump Design
CAUTION
The pump is partly-completed machinery without safeguard. The pump cannot in itself perform a specific
function, and will only be complete once incorporated into the system including all necessary protective
means/guard and control power circuit. Finally, the system integrator shall take all appropriate measures to
ensure that partly completed machinery can be placed on the market only if it satisfies the relevant provisions
with EN 60204-1 and EN ISO 12100. Safety distance and slot/gap shall comply with table 1, 3, 4 of EN ISO
13857.
The following installation instructions are only applicable when the installation has been designed
following the pump dimensional drawings.
1. Run the cable so that it has no sharp bends, is not pinched, and cannot be drawn into the pump inlet.