Pump Application Conditions 

Conditions

 

Description

 

Liquid Temperature

 

5°C to 40°C (41°F to 104°F)

 

ph liquid

 

5-8

 

Rated Output Variation

 

±10%

 

Voltage Variation without overheating

 

±10%, provided that it does not run

 

Frequency Variation

 

±1%

 

Maximum Allowable Pressure

 

0.2 MPa (2kgf/cm2) – Discharge pressure

 

 

 

Pump Installation 

WARNING

 

 

Before installing the pump, check if the cable and cable entry have not been damaged  during 

transportation. 

 

Be aware of the pump's center of gravity and weight. If the pump is not suspended properly, it 

may lead to injury. 

 

Never use the pump cable to suspend the pump. Doing so will damage the cab and may cause 

electric shock or fire. 

 

DO NOT dismantle the product before/during installation without any authorized instructions from 

PRORIL 

 

NOTICE 

 

The following installation requirement must be implemented: 

 

 

Use the pump dimensional drawing to ensure proper installation. If you have any questions, please 

contact our representative or company. 

 

Provide a suitable protective barrier around the pump working area. 

 

Check for any explosion risk before pipe welding or use of any electrical hand tools. 

 

Remove any remaining debris from the inlet piping system before installing the pump. 

 

 

 

 

CAUTION 

 

During piping work be aware if welding sparks, paint, concrete, etc. come in contact with the pump, it may cause 

the pump to malfunction, and current leakage or electric shock may occur. 

 

Pump Design 

 

 

 

CAUTION 

 

The pump is partly-completed machinery without safeguard. The pump cannot in itself perform a specific 

function, and will only be complete once incorporated into the system including all necessary protective 

means/guard and control power circuit. Finally, the system integrator shall take all appropriate measures to 

ensure that partly completed machinery can be placed on the market only if it satisfies the relevant provisions 

with EN 60204-1 and EN ISO 12100. Safety distance and slot/gap shall comply with table 1, 3, 4 of EN ISO 

13857. 

 

The following installation instructions are only applicable when the installation has been designed 

following the pump dimensional drawings. 

 

1.   Run the cable so that it has no sharp bends, is not pinched, and cannot be drawn into the pump inlet. 

Installation

 

 

 

 

 

Содержание GOCUT Series

Страница 1: ...2 Download the manual in your preferred language scan the QR code...

Страница 2: ...Float Switch Loction Installation Requirement Electrical Connection______________________________________________________________ 8 Connection Requirements External Protection Devices Grounding Earth...

Страница 3: ...s and health problems damage to the product and or product malfunction Hazard Notice Symbols DANGER A hazardous situation which if not avoided will result in death or serious injury WARNING A hazardou...

Страница 4: ...f long exposure to noise Never run the pump without water do not operate the pump out of water or insufficient water Do not use the pump if the power cable is damaged If you have any questions please...

Страница 5: ...se Turn the impeller by hand before using the pump Check the seals and the cable entry Additional information on the product specific information e g dimensions specifications performance curves for t...

Страница 6: ...und the pump working area Check for any explosion risk before pipe welding or use of any electrical hand tools Remove any remaining debris from the inlet piping system before installing the pump CAUTI...

Страница 7: ...OTICE For the water level required for operating the pump refer to the pump s dimensional drawing that can be obtained from our representative or company 6 Make sure that the impeller rotation is corr...

Страница 8: ...alog pressure sensor Two additional safety float switches can be installed in the dedicated Control System for high level and dry running alarm The thermal contacts thermistors must be in use The cabl...

Страница 9: ...to Operation Never operate the pump without safety devices installed Never operate the pump with the discharge valve closed Make sure that all safety guards are in place and secure Make sure you have...

Страница 10: ...tation of the impeller If the starting jerk is counterclockwise seen from above the direction of its rotation is correct If the direction of rotation is incorrect two of the wires should be switched c...

Страница 11: ...checkups and preventive maintenance will ensure a more reliable and safe operation An initial inspection of the pump within 3 to 4 months after installation is recommended Subsequent inspections maint...

Страница 12: ...13 CUTTING HAZARD Worn impellers often have very sharp edges Be very careful when replacing them Troubleshooting...

Страница 13: ...ate 5 Mech Seal 12 Strainer 6 Seal bracket 13 Base plate 7 Oil seal No enomination No Denomination 1 Motor 7 Agitator 2 Mech Seal 8 Wear plate 3 Pump casing 9 Inlet plate 4 Oil seal 10 Strainer 5 Shaf...

Страница 14: ...ischarge elbow 4 Oil seal 5 Shaft sleeve 6 Impeller enomination No Denomination 1 Motor 7 Pump casing 2 Mech Seal 8 Flange 3 Pump casing 9 Discharge elbow 4 Oil seal 5 Shaft sleeve 6 Impeller Part Lis...

Страница 15: ...16 enomination No Denomination 1 Motor 7 Pump casing 2 Mech Seal 8 Flange 3 Pump casing 9 Discharge elbow 4 Oil seal 5 Shaft sleeve 6 Impeller Part List SAVVY JUMBO BASE Pumps 4 5...

Страница 16: ...17...

Страница 17: ...ion Examples CP 1026 2018 November 1026th pump BS 1496 2017 August 1496th pump BN 1135 2017 December 1135th pump B 2017 P November C 2018 Q October D 2019 R September E 2020 S August F 2021 T July G 2...

Страница 18: ...UANGHUA RD DASHE DISTRICT KAOHSIUNG CITY 815 TAIWAN TEL 886 7 351 2306 MADE IN TAIWAN REV MN 2021 01 2021 PRORIL The original instruction is in English All non English instructions are translations of...

Отзывы: