background image

DANGER:

 

To reduce the risk of electric shock: Always unplug this furnishing 

from the electrical outlet before cleaning or servicing.

WAR N I N G

:

 

To reduce the risk of death, serious injury, or property damage, read 

and follow this safety information and the provided instructions when 

assembling this product. Do not change or replace components and 

accessories provided by Propr Office.

INSTALL ONLY APPROVED WORK SURFACES 
Work surface must be at least ¾" thick and weigh no more than 5 lb. 

per square foot (For example, a 2'x6' desktop should weigh no more 

than 60 lb). Do not exceed a maximum weight for the desktop of 75 

lb. To prevent table from tipping or collapsing, make sure the desk 

frame is not overloaded by the weight of tabletop and objects you 

plan to put on the table. If you are unsure, contact customer service.

KEEP AWAY FROM CHILDREN 
This table system is not designed for use in homes or other areas 

accessible by small children. For indoor commercial office use only.

BE CAREFUL WHEN ADJUSTING DESK HEIGHT
Body parts and property can be caught between the moving work 

surface and an immobile obstacle (such as shelves, furniture, win-

dow sills, or walls). Keep at least one inch of clearance around desk 

and make sure nothing is in table’s path for its entire range of motion.
Before raising or lowering:

•  Check surroundings on all sides of desk are clear

•  Make sure corded objects will not be pulled off table or cause 

other objects to fall

•  Make sure desk power cord moves freely as desk moves up 

and down

DO NOT OVERLOAD DESK 
To prevent table from tipping or collapsing, make sure the desk frame 

is not overloaded by the weight of tabletop and objects on table. 

Evenly distribute load; excess loads near edges can reduce stability 

and lead to tip over. 

•  Do not exceed maximum load (including weight of desktop) of 

200 lb. (91Kg) for two-leg configuration.

•  Do not exceed edge load of 25 lb. when positioning monitors 

or mounting accessories.

•  Do not sit or stand on table.  

USE CARE WHEN MOVING DESK 

•  Clear objects and equipment from table before moving to 

reduce the risk of tipping over. 

•  Adjust the desk to its lowest height before moving.

•  To disconnect, remove plug from outlet.

•  Do not move a loaded desk.

DO NOT OPEN ELECTRICAL COMPONENTS
Do not attempt to service table components. There are no user-ser-

viceable parts inside the motor control units or table legs. If your 

table needs service, contact customer service. Never operate this 

table if it has a damaged cord or plug. 

KEEP TABLE FRAME DRY
Keep all electrical components away from water and high humidity. 

Clean only with a dry or slightly damp cloth. Do not spray cleaning 

solutions directly onto table system.

GROUNDING INSTRUCTIONS
This product is equipped with a cord having an equipment-ground-

ing conductor and a grounding plug. Use only the cord provided.  

Make sure that  the product is connected to an outlet having the 

same  configuration  as  the  plug  (as  shown  in  Illustration  A)  that  is 

properly installed and grounded in accordance with all local codes 

and ordinances.

Do not modify the plug provided with the product – if it will not fit the 

outlet, have a proper outlet installed by a qualified electrician. 

•  No adapters are to be used with this product.

•  Keep cord away from heated surfaces.

Grounded

Outlet

Grounded Outlet Box

Grounding

Pin

ILLUSTRATION A

1"

1"

1"

1"

1"

1"

S A F E T Y   I N F O R M AT I O N

proproffice.com          9

P E R C H   A D J U S TA B L E   H E I G H T   B E N C H   S Y S T E M

Содержание L48 W24

Страница 1: ...om tip overs Never stand on furniture Furniture intended for placement on floor Do not place items over 200lb on furniture C L E A N I N G C A R E Clean surfaces with a dry or damp soft cloth Do not use abrasive oil or chemical based cleaners It is recommended to use coasters to protect surface from heat and water Do not leave spills unattended D E S K T O P D I M E N S I O N S L48 W24 L48 W30 L60...

Страница 2: ...mm Self Threading Screw 16 10 M8 1 25x16mm Screw 4 11 M8 Split Washer 4 12 M8 Nut 4 13 M4 0 7x6mm Screw 4 14 Control Box 2 15 Hand switch 2 16 Power Cord 2 17 HAT Channel 2 For tables equal or greater than 72 18 10 x Screw 48 3 18 4 13 1 8 12 11 10 14 7 9 2 16 15 5 17 DO NOT remove the foam surrounding the motor proproffice com 2 P E R C H A D J U S TA B L E H E I G H T B E N C H S Y S T E M ...

Страница 3: ...their own fastening threads if none are already present An average fastening torque of 8Nm 6 lbs ft will be required to initially engage the screw in the hole The maximum tightening torque for these screws is 20Nm 15 lbs ft Repeat as necessary for remaining columns 2 Attach ganging tube to columns Assemble using the M8 1 25 Tooth Lock Washer Nut 2 per column The maximum tightening torque for these...

Страница 4: ... channel so that all tabs are secured into the tray 5 Attach work surface to column assemblies Flip table into upright position Top supports should be mounted 1 5 from edge of work surface Be sure to use approved screws per the table top supplier A S S E M B LY I N S T R U C T I O N S proproffice com 4 P E R C H A D J U S TA B L E H E I G H T B E N C H S Y S T E M ...

Страница 5: ... ganging bracket The maximum tightening torque for these screws is 20Nm 14 8 ft lbs A socket wrench is recommended for this step to hold the nut in place Repeat for both sides 7 For tables equal to or greater than 66 Attach the HAT channel Feed the motor cables through the HAT channel cut out A S S E M B LY I N S T R U C T I O N S Snap on the ganging bracket covers The covers will self secure when...

Страница 6: ...table top supplier 9 Connect the motor cables to the control box The motor cable plug connection has to click into place Connections to the control box M1 M2 Connectors for the columns HS Connectors for the handset AC Connector for the power cord 3 pin 10 Connect the hand switch HS cable to the control box A S S E M B LY I N S T R U C T I O N S proproffice com 6 P E R C H A D J U S TA B L E H E I ...

Страница 7: ...rap cables and or cords around the columns 13 Connect side by side tables For units specified to use a side to side connector attach lower tray to the bottom of the ganging bracket of each bench using the M4 0 7x6mm length screws The maximum tightening torque for these screws is 4Nm 35in lbs Once installed the upper tray can be slid on to fit A S S E M B LY I N S T R U C T I O N S proproffice com ...

Страница 8: ...t in the tray and slide the block to lock it into place Install U channel to tray Remove the punch out features from both sides of the u channel Power block will wedge into the channel between the punch out features secure by squeezing the u channel and locking the tabs into the tray For simplex receptacle removal Insert ends of Simplex removal tool into slots above and below receptacle shown and ...

Страница 9: ...y the weight of tabletop and objects on table Evenly distribute load excess loads near edges can reduce stability and lead to tip over Do not exceed maximum load including weight of desktop of 200 lb 91Kg for two leg configuration Do not exceed edge load of 25 lb when positioning monitors or mounting accessories Do not sit or stand on table USE CARE WHEN MOVING DESK Clear objects and equipment fro...

Страница 10: ... S T R U C T I O N S T R O U B L E S H O O T I N G ISSUE SOURCE SOLUTION Desktop does not move No power supply Plug in power cord If necessary check connections on control unit Loose or no connection to legs Verify table leg motor power cords are connected to control box Loose or no connection to the hand switch Verify hand switch power cord is connected to control box Max lifting capacity is exce...

Страница 11: ...ld and Commercial Furnishings CSA C22 2 68 Issued 2009 09 01 Ed 7 R2014 Motor Operated Appliances Household and Commercial Meets BIFMA x5 5 2014 ILLUSTRATION B Single Stage Dual Stage T E C H N I C A L D ATA S TA N D A R D S C E R T I F I C AT I O N S GENERAL CONTROL BOX Power supply 120 VAC 10 60 Hz Standby power consumption primarily 0 3 W Operating temperature 0 35 C Protection class IP20 Maxim...