background image

Perch Height Adjustable

Bench System

U S E R   G U I D E

            W A R N I N G

Serious or fatal crushing injuries can occur from furniture tip-over.  

To help prevent tip-over, read this entire warning.
To further reduce the risk of serious injury and death from tip-overs:

•  Never stand on furniture

•  Furniture intended for placement on floor

•  Do not place items over 200lb on furniture

!

C L E A N I N G   +   C A R E

Clean surfaces with a dry or damp soft cloth. Do not use 

abrasive, oil or chemical based cleaners. It is recommended to 

use coasters to protect surface from heat and water. Do not 

leave spills unattended.

D E S K T O P   D I M E N S I O N S

•  L48 W24
•  L48 W30

•  L60 W24
•  L60 W30

•  L72 W24
•  L72 W30

proproffice.com          1

Содержание L48 W24

Страница 1: ...om tip overs Never stand on furniture Furniture intended for placement on floor Do not place items over 200lb on furniture C L E A N I N G C A R E Clean surfaces with a dry or damp soft cloth Do not use abrasive oil or chemical based cleaners It is recommended to use coasters to protect surface from heat and water Do not leave spills unattended D E S K T O P D I M E N S I O N S L48 W24 L48 W30 L60...

Страница 2: ...mm Self Threading Screw 16 10 M8 1 25x16mm Screw 4 11 M8 Split Washer 4 12 M8 Nut 4 13 M4 0 7x6mm Screw 4 14 Control Box 2 15 Hand switch 2 16 Power Cord 2 17 HAT Channel 2 For tables equal or greater than 72 18 10 x Screw 48 3 18 4 13 1 8 12 11 10 14 7 9 2 16 15 5 17 DO NOT remove the foam surrounding the motor proproffice com 2 P E R C H A D J U S TA B L E H E I G H T B E N C H S Y S T E M ...

Страница 3: ...their own fastening threads if none are already present An average fastening torque of 8Nm 6 lbs ft will be required to initially engage the screw in the hole The maximum tightening torque for these screws is 20Nm 15 lbs ft Repeat as necessary for remaining columns 2 Attach ganging tube to columns Assemble using the M8 1 25 Tooth Lock Washer Nut 2 per column The maximum tightening torque for these...

Страница 4: ... channel so that all tabs are secured into the tray 5 Attach work surface to column assemblies Flip table into upright position Top supports should be mounted 1 5 from edge of work surface Be sure to use approved screws per the table top supplier A S S E M B LY I N S T R U C T I O N S proproffice com 4 P E R C H A D J U S TA B L E H E I G H T B E N C H S Y S T E M ...

Страница 5: ... ganging bracket The maximum tightening torque for these screws is 20Nm 14 8 ft lbs A socket wrench is recommended for this step to hold the nut in place Repeat for both sides 7 For tables equal to or greater than 66 Attach the HAT channel Feed the motor cables through the HAT channel cut out A S S E M B LY I N S T R U C T I O N S Snap on the ganging bracket covers The covers will self secure when...

Страница 6: ...table top supplier 9 Connect the motor cables to the control box The motor cable plug connection has to click into place Connections to the control box M1 M2 Connectors for the columns HS Connectors for the handset AC Connector for the power cord 3 pin 10 Connect the hand switch HS cable to the control box A S S E M B LY I N S T R U C T I O N S proproffice com 6 P E R C H A D J U S TA B L E H E I ...

Страница 7: ...rap cables and or cords around the columns 13 Connect side by side tables For units specified to use a side to side connector attach lower tray to the bottom of the ganging bracket of each bench using the M4 0 7x6mm length screws The maximum tightening torque for these screws is 4Nm 35in lbs Once installed the upper tray can be slid on to fit A S S E M B LY I N S T R U C T I O N S proproffice com ...

Страница 8: ...t in the tray and slide the block to lock it into place Install U channel to tray Remove the punch out features from both sides of the u channel Power block will wedge into the channel between the punch out features secure by squeezing the u channel and locking the tabs into the tray For simplex receptacle removal Insert ends of Simplex removal tool into slots above and below receptacle shown and ...

Страница 9: ...y the weight of tabletop and objects on table Evenly distribute load excess loads near edges can reduce stability and lead to tip over Do not exceed maximum load including weight of desktop of 200 lb 91Kg for two leg configuration Do not exceed edge load of 25 lb when positioning monitors or mounting accessories Do not sit or stand on table USE CARE WHEN MOVING DESK Clear objects and equipment fro...

Страница 10: ... S T R U C T I O N S T R O U B L E S H O O T I N G ISSUE SOURCE SOLUTION Desktop does not move No power supply Plug in power cord If necessary check connections on control unit Loose or no connection to legs Verify table leg motor power cords are connected to control box Loose or no connection to the hand switch Verify hand switch power cord is connected to control box Max lifting capacity is exce...

Страница 11: ...ld and Commercial Furnishings CSA C22 2 68 Issued 2009 09 01 Ed 7 R2014 Motor Operated Appliances Household and Commercial Meets BIFMA x5 5 2014 ILLUSTRATION B Single Stage Dual Stage T E C H N I C A L D ATA S TA N D A R D S C E R T I F I C AT I O N S GENERAL CONTROL BOX Power supply 120 VAC 10 60 Hz Standby power consumption primarily 0 3 W Operating temperature 0 35 C Protection class IP20 Maxim...