PROBOIL
.2
Pro
duo
2 Way Dispenser Installation Guide
⚠
These instructions should be used in
These instructions should be used in
These instructions should be used in
These instructions should be used in conjunction with the principal
conjunction with the principal
conjunction with the principal
conjunction with the principal instruction booklet suppl
instruction booklet suppl
instruction booklet suppl
instruction booklet supplied
ied
ied
ied, you should
, you should
, you should
, you should
substitute
substitute
substitute
substitute the section referring to the installation of the 3in1 tap with this guide.
the section referring to the installation of the 3in1 tap with this guide.
the section referring to the installation of the 3in1 tap with this guide.
the section referring to the installation of the 3in1 tap with this guide.
Important Technical Data
Important Technical Data
Important Technical Data
Important Technical Data
Minimum operating pressure (cold): 1.5 bar
Maximum operating pressure: 5.5 bar*
Flow characteristics: Dual flow filtered water, Boiled water through centre insulated spout channel.
*If these pressures are exceeded, even for short periods, damage can result. In these instances a pressure reducing valve should be
installed.
This product is manufactured in accordance with recognised European standards. Please ensure that your product is fitted in
accordance with Local Water Byelaws.
. .
. A
A
A
A su
su
su
suitable non
itable non
itable non
itable non----return (check) valve
return (check) valve
return (check) valve
return (check) valve should be installed to
should be installed to
should be installed to
should be installed to the cold supply
the cold supply
the cold supply
the cold supply to prevent backflow
to prevent backflow
to prevent backflow
to prevent backflow, a
non-return valve on the cold supply before 3 way tee (F1) is required (see instructions key).
These installation guidelines have been prepared for your direction and you must exercise due care at all times. We do not accept
responsibility for problems that may occur through improper installation. Whilst assembling the tap take care not to accidentally
loosen any factory fixed assemblies.
This tap has been 100% assembly tested; therefore you may expect a small residual amount of water to remain in the tap when
delivered. Any water marks can be removed using the supplied care advice.
Installation Preparation
Installation Preparation
Installation Preparation
Installation Preparation
⚠
Before installing the new mixer it is essential that you thoroughly flush through the supply pipes in order to remove any
remaining solder, swarf or impurities from your system. Failure to carry out this simple procedure could cause problems or damage to
the workings of the dispenser or boiler.
We recommend installing particle filters (not shown) and an isolation valve to the cold feed pipe in an accessible position. This will
help to prevent premature failure of the valves and ease any future maintenance.
Ensure you have suitable domestic cold water pressure before installing this product (see technical data for more information
Ensure you have suitable domestic cold water pressure before installing this product (see technical data for more information
Ensure you have suitable domestic cold water pressure before installing this product (see technical data for more information
Ensure you have suitable domestic cold water pressure before installing this product (see technical data for more information).
).
).
).
All parts should be removed from their packaging and inspected for any transport damage and that all parts are present prior to
installation.
Shut off your water supply system, ensure that your mains stopcock is closed. Open the lowest cold tap in the house and allow the
water to run until fully stopped.
If replacing an existing tap, remove the tap & clean the end of the feed pipes using wire wool, the tap hole area should be free from
dirt and sealant. Loosely position the tap and tail pipes to check if any alteration to the existing pipework is required. If this is the case
do this now.
If replacing an existing tap, remove the tap & clean the end of the feed pipes using wire wool,
the tap hole area should be free from dirt and sealant. Loosely position the tap and tail pipes to
check if any alteration to the existing pipework is required. If this is the case do this now.
This dispenser requires a Ø35mm tap hole.
This dispenser is designed to be installed in a worktop with a maximum thickness of 50mm.