background image

The symbol is used to indicate that some hazardous live terminals are involved within this apparatus, even 
under the normal operating conditions, which may be sufficient to constitute the risk of electric shock or 
death.

The symbol is used in the service documentation to indicate that specific component shall be replaced 
only by the component specified in that documentation for safety reasons.

Protective grounding terminal

Alternating current/voltage

Hazardous live terminal

ON:

 Denotes the apparatus is turned on

OFF:

 Denotes the apparatus is turned off.

WARNING:

 Describes precautions that should be observed to prevent the danger of injury or death to the operator.

CAUTION:

 Describes precautions that should be observed to prevent danger of the apparatus.

IMPORTANT SAFETY INSTRUCTIONS

·

Read these instructions.

·

Keep these instructions.

·

Heed all warning.

·

Follow all instructions.

Water & Moisture

·

The apparatus should be protected from moisture and 
rain, can not used near water, for example: near bath-
tub, kitchen sink or a swimming pool, etc.

·

Heat

The apparatus should be located away from the heat 
source such as radiators, stoves or other appliances 
that produce heat.

·

Ventilation

Do not block areas of ventilation opening. Failure to 
do could result in fire. Always install accordance with 
the manufacturer's instructions.

·

Object and Liquid Entry

Objects do not fall into and liquids are not spilled into 
the inside of the apparatus for safety.

·

Power Cord and Plug

Protect the power cord from being walked on or pinched  
particularly at plugs, convenience receptacles, and the 
point where they exit from the apparatus. 

Do not defeat the safety purpose of the polarized or 
grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong is provided for your safety. 
If the provided plug does not fit into your outlet, refer to 
electrician for replacement.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

IMPORTANT SAFETY SYMBOLS

·

Power Supply

The apparatus should be connected to the power supply 

only of the type as marked on the apparatus or described 
in the manual. Failure to do could result in damage to the 
product and possibly the user. 

Unplug this apparatus during lightning storms or when 
unused for long periods of time.

·

Fuse

To prevent the risk of fire and damaging the unit, please 
use only of the recommended fuse type as described in 
the manual. Before replacing the fuse, make sure the unit 
turned off and disconnected from the AC outlet.

·

Electrical Connection

Improper electrical wiring may invalidate the product war-
ranty.

·

Cleaning

Clean only with a dry cloth. Do not use any solvents such 
as benzol or alcohol.

·

Servicing

Do not implement any servicing other than those means 
described in the manual. Refer all servicing to qualified 
service personnel only.

·

Only use accessories/attachments or parts recommended 
by the manufacturer.

·

Warning

Please remember the high sound pressure do not only 
temporarily damage your sense of hearing, but can also 
cause permanent damage. Be careful to select a suitable 
volume.

Mono inputs

Microphone inputs (XENYX Mic Preamp)

Type 

XLR, electronically balanced,
discrete input circuit 

Mic E.I.N. (20 Hz - 20 kHz)
@ 0 

Ω

 source resistance

@ 50 

Ω

 source resistance

@ 150 

Ω

 source resistance

-134 dB / 135.7 dB A-weighted
-131 dB / 133.3 dB A-weighted
-129 dB / 130.5 dB A-weighted

Frequency response

<10 Hz -150 kHz (-1 dB),
<10 Hz -200 kHz (-3 dB)

Gain range

+10 to +60 dB

Max. Input level

+12 dBu @ +10 dB gain

Impedance

approx. 2.6 k

 balanced

Ω

110 dB / 112 dB A-weighted

Signal-to noise ratio

(0 dBu In @ +22 dB gain)

Distortion (THD+ N)

0.005% / 0.004% A-weighted

Line input

Type 

Impedance

Gain range
Max. Input level

1

Fade-out attenuation
(Crosstalk attenuation)

Main fader closed
Channel muted
Channel fader closed

Frequency response

Microphone input to main out

<10 Hz - 90 kHz 
<10 Hz - 160 kHz 

+0 dB / -1 dB 
+0 dB / -3 dB 

Stereo inputs

Type

1/4

 TRS connector,

Impedance

Max. Input level

electronically balanced
approx. 20 k

 

Ω

+22 dBu 

EQ mono channels

EQ stereo channels

9

5.SPECIFICATIONS

1/4

 TRS connector,

electronically balanced
approx. 20

 banlanced 

Ω

10 k

 unbanlanced 

Ω

-10 to +40 dB

30 dBu

90 dB
89.5 dB
89 dB

Low
Mid
High

Low
Mid
High

80 Hz / 15 dB 
2.5 kHz / 15 dB 
12 kHz / 15 dB 

80 Hz / 15 dB 
2.5 kHz / 15 dB 
12 kHz / 15 dB 

Aux sends

Stereo aux return

Type
Impedance
Max.output level

1/4

T

  S connector, unbalanced

approx. 20 k

 

Ω

+22 dBu 

Main outputs

Type
Impedance
Max.output level

XLR electronically balanced
approx. 240  bal./ 120  unbal. 

Ω

Ω

+28 dBu 

Control room outputs

Type
Impedance
Max.output level

1/4

TS connector,  unbal.

approx. 120   

Ω

+22 dBu 

Headphones output

Type
Max.output level

1/4

TRS connector,  unbalanced

+19 dBu / 150

(+25 dBu)

Ω

DSP

Converter

24-bit Texas Instruments
24-bit Sigma-Delta.
64/128-times oversampling
40 kHz

Sampling rate 

2

Main mix system data

Noise
Main mix @ -

Channel fader -

 

Main mix @ 0 dB, 
Channel fader -

 

Main mix @ 0 dB, 
Channel fader @ 0 dB

-105 dB / -108 dB A-weighted

-95 dB / -97 dB A-weighted

-82.5 dB / -85 dB A-weighted

Power supply

Mains voltage 
Power consumption
Fuse

100 -240 V~, 50/60 Hz
40 W

Mains connection

Standard IEC receptacle

100 -240 V~, T  1.6  A  H  250V

Physical

1204FX

Dimensions (H x W x D)

245 x 324 x 86 mm

2.1kg

weight (net)

1404FX

Dimensions (H x W x D)

298 x 324 x 86 mm

2.3kg

weight (net)

1604FX

1804FX

Measuring conditions:

1:     1kHz rel.to 0 dBu; 20 Hz - 20 kHz, line input; main output; unity gain.

2:      20Hz - 20kHz; measured at main output. Channels 1 - 4 unity gain: EQ flat; all
         channels on main mix; channels 1/3 as far left as possible, channels 2/4 as far
         right as possible. Reference = +6 dBu. 

LongerdB is constantly striving to manintain the highest professional standards. As a 
result of these efforts, modifications may be made from time to existing products without
prior notice. Specifications and appearance may differ from those listed or illustrated. 

1/4

 TRS connector,

Type

electronically balanced
approx. 20 k  bal. /10 k  unbal. 

Ω

Ω

+22 dBu 

Impedance
Max.input level

Dimensions (H x W x D)

351 x 324 x 86 mm

2.5kg

weight (net)

Dimensions (H x W x D)

404 x 324 x 86 mm

2.7kg

weight (net)

MX Series Mixer